GS82032AT-180/166/150/133/100/66/4/5/6
Undershoot Measurement and Timing
Overshoot Measurement and Timing
V
IH
20% tKC
V
+- 2.0 V
DD
V
SS
50%
50%
V
DD
V
– 2.0 V
SS
20% tKC
V
IL
Capacitance
(T = 25°C, f = 1 MHZ, V = 3.3 V)
A
DD
Parameter
Symbol
Test conditions
Typ.
Max.
Unit
C
V
= 3.3 V
= 0 V
Control Input Capacitance
Input Capacitance
3
4
6
4
5
7
pF
pF
pF
I
DD
C
V
IN
IN
C
V
= 0 V
OUT
Output Capacitance
OUT
Note:
This parameter is sample tested.
AC Test Conditions
Parameter
Conditions
Input high level
Input low level
2.3 V
0.2 V
Input slew rate
1 V/ns
1.25 V
1.25 V
Fig. 1& 2
Input reference level
Output reference level
Output load
Notes:
1. Include scope and jig capacitance.
2. Test conditions as specified with output loading as shown in Fig. 1 unless otherwise noted.
3. Output Load 2 for t , t , t and t
LZ HZ OLZ
OHZ
4. Device is deselected as defined by the Truth Table.
Output Load 2
2.5 V
Output Load 1
DQ
225Ω
225Ω
DQ
*
50Ω
VT = 1.25 V
30pF
*
5pF
* Distributed Test Jig Capacitance
Rev: 1.12 10/2004
11/22
© 2000, GSI Technology
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.