GS71024T/U
AC Test Conditions
Output Load 1
Parameter
Conditions
DQ
V
= 2.4 V
Input high level
IH
1
30pF
50Ω
V = 0.4 V
Input low level
Input rise time
IL
VT = 1.4 V
tr = 1 V/ns
tf = 1 V/ns
1.4 V
Input fall time
Output Load 2
Input reference level
Output reference level
Output load
3.3 V
1.4 V
Fig. 1& 2
589Ω
434Ω
DQ
Notes:
1
5pF
1. Include scope and jig capacitance.
2. Test conditions as specified with output loading as shown in Fig. 1
unless otherwise noted
3. Output load 2 for t , t , t
and t
.
OHZ
LZ HZ OLZ
Power Supply Currents
0 to 70°C
10 ns
-40 to 85°C
12 ns 15 ns
Parameter
Symbol
Test Conditions
CE ≤ V
8 ns
9 ns
12 ns
15 ns
10 ns
IL
All other inputs
Operating
Supply
I
≥ V or ≤ V
190 mA 170 mA 160 mA 130 mA 110 mA 165 mA 135 mA 115 mA
DD
IH
IL
Current
Min. cycle time
= 0 mA
I
OUT
CE ≥ V
IH
Standby
Current
All other inputs
≥ V or ≤V
I
45 mA 45 mA 40 mA 35 mA 30 mA 45 mA 40 mA 35 mA
SB1
IH
IL
Min. cycle time
CE ≥ V – 0.2 V
DD
Standby
Current
I
All other inputs
10 mA
15 mA
SB2
≥ V – 0.2 V or ≤ 0.2 V
DD
Rev: 1.05 11/2004
5/13
© 1999, GSI Technology