欢迎访问ic37.com |
会员登录 免费注册
发布采购

GS9078ACNE3 参数 Datasheet PDF下载

GS9078ACNE3图片预览
型号: GS9078ACNE3
PDF下载: 下载PDF文件 查看货源
内容描述: GS9078A HD - LINX -R II多速率电缆驱动器 [GS9078A HD-LINX-R II Multi-Rate Cable Driver]
分类和应用: 线路驱动器或接收器驱动程序和接口信息通信管理
文件页数/大小: 14 页 / 293 K
品牌: GENNUM [ GENNUM CORPORATION ]
 浏览型号GS9078ACNE3的Datasheet PDF文件第4页浏览型号GS9078ACNE3的Datasheet PDF文件第5页浏览型号GS9078ACNE3的Datasheet PDF文件第6页浏览型号GS9078ACNE3的Datasheet PDF文件第7页浏览型号GS9078ACNE3的Datasheet PDF文件第9页浏览型号GS9078ACNE3的Datasheet PDF文件第10页浏览型号GS9078ACNE3的Datasheet PDF文件第11页浏览型号GS9078ACNE3的Datasheet PDF文件第12页  
GS9078A Data Sheet  
4. Detailed Description  
4.1 Input Interfacing  
S
DI/SDI are high impedance differential inputs. The equivalent input circuit is shown  
in Figure 3-1  
.
Several conditions must be observed when interfacing to these inputs:  
The differential input signal amplitude must be between 300 and 2000mVpp.  
The common mode voltage range must be as specified in the DC Electrical  
Characteristics on page 5.  
For input trace lengths longer than approximately 1cm, the inputs should be  
terminated as shown in the Typical Application Circuit.  
The GS9078A inputs are self-biased, allowing for simple AC coupling to the device.  
For serial digital video, a minimum capacitor value of 4.7µF should be used to allow  
coupling of pathological test signals. A tantalum capacitor is recommended.  
4.2 Output Interfacing  
The GS9078A outputs are current mode, and will drive 800mV into a 75Ω load.  
These outputs are protected from accidental static damage with internal static  
protection diodes.  
The SMPTE 344M and SMPTE 259M standards require that the output of a cable  
driver have a source impedance of 75Ω and a return loss of at least 15dB between  
5MHz and 540MHz.  
In order for an SDI output circuit using the GS9078A to meet this specification, the  
output application circuit shown in Typical Application Circuit on page 11 is  
recommended.  
The value of L  
will vary depending on the PCB layout, with a typical value of  
COMP  
5.6nH. A 4.7µF capacitor is used for AC coupling the output of the device. This  
value is chosen to ensure that pathological signals can be coupled without a  
significant DC component occurring. Please see Application Information on  
page 11 for more details.  
34165 - 4 March 2006  
8 of 14