MB90560/565 Series
• PLL guaranteed operation range
Relationship between internal operating clock frequency and power supply voltage
PLL guaranteed operation range
(MB90567/568/F568 : 3.0 V to 3.6 V, fCP = 3 MHz to 16 MHz)
(MB90V560 : 3.0 V to 3.6 V, fCP = 3 MHz to 12 MHz)
3.6
PLL guaranteed
operation range
A/D converter
guaranteed
operation range
3.0
2.7
Guaranteed operation range
for MB90V560
(3.0 V to 3.6 V,
Guaranteed operation range for MB90567/568/F568
(3.0 V to 3.6 V, fCP = 1.5 MHz to 16 MHz)
(2.7 V to 3.6 V, fCP = 1.5 MHz to 8 MHz)
fCP = 1.5 MHz to 12 MHz)
1.5
3
8
12
16
Internal Clock fCP (MHz)
Relationship between oscillation frequency and internal operating clock frequency
×4 ×3
×2
×1
16
12
9
8
No multiplier
6
4
3
2
1.5
3
4
6
8
12
16
Source Oscillation Clock fC (MHz)
The AC ratings are specified for the following measurement reference voltages.
• Input signal waveform
• Output signal waveform
Hysteresis input pin
Output pin
0.8 VCC
2.4 V
0.2 VCC
0.8 V
Pins other than hysteresis input or MD input pins
0.7 VCC
0.3 VCC
75