MB15F72SP
(Continued)
(VCC = 2.4 V to 3.6 V, Ta = −40 °C to +85 °C)
Value
Unit
Parameter
Symbol
Condition
VCC = Vp = 2.7 V,
VDOH = Vp/2,
Ta = +25 °C
Min.
Typ.
Max.
CS bit = “H”
CS bit = “L”
CS bit = “H”
CS bit = “L”
−6.0
mA
mA
mA
mA
“H” level output
current
DoIF
DoRF
*4
IDOH
−1.5
6.0
VCC = Vp = 2.7 V,
VDOL = Vp/2,
Ta = +25 °C
“L” level output
current
DoIF
DoRF
IDOL
1.5
*5
IDOL/IDOH IDOMT
vs. VDO IDOVD
VDO = Vp / 2
3
%
%
*6
*7
Charge pump
current rate
0.5 V ≤ VDO ≤ Vp − 0.5 V
10
−40 °C ≤ Ta ≤ +85 °C,
VDO = Vp / 2
vs.Ta
IDOTA
10
%
*1 : finIF = 270 MHz, fosc = 12.8 MHz, VCCIF = VpIF = 2.7 V, SWIF = 0, Ta = +25°C, in locking state.
*2 : finRF = 910 MHz, fosc = 12.8 MHz, VCCRF = VpRF = 2.7 V, SWRF = 0, Ta = +25°C, in locking state.
*3 : AC coupling. 1000pF capacitor is connected under the condition of min. operating frequency.
*4 : The symbol “–” (minus) means direction of current flow.
*5 : VCC = Vp = 2.7 V, Ta = +25°C
(||I3| – |I4||)/[(|I3| + |I4|)/2] × 100(%)
*6 : VCC = Vp = 2.7 V, Ta = +25°C (Applied to each IDOL, IDOH)
[(||I2| – |I1||)/2]/[(|I1| + |I2|)/2] × 100(%)
*7 : VCC = Vp = 2.7 V, Ta = +25°C (Applied to each IDOL, IDOH)
[||IDO(+85°C)| –|IDO(–40°C)||/2]/[|IDO(+85°C)| + |IDO(–40°C)|/2] × 100(%)
*8 : fosc = 12.8 MHz, VCCRF = VpRF = VCCIF = 2.7 V, Ta = +25°C
I1
I3
I4
I2
IDOL
IDOH
I1
Vp/2
Vp − 0.5 Vp
0.5
Charge pump output voltage (V)
7