MB39A104
■ ABSOLUTE MAXIMUM RATINGS
Rating
Parameter
Symbol
Condition
Unit
Max
Min
Power supply voltage
Output current
VCC
IO
VCC, VCCO terminal
OUT1, OUT2 terminal
Duty ≤ 5% (t = 1/fOSC×Duty)
Ta ≤ +25 °C
20
60
V
mA
mA
mW
°C
Output peak current
Power dissipation
Storage temperature
IOP
700
740*
+125
PD
TSTG
−55
* : The packages are mounted on the epoxy board (10 cm × 10 cm).
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
■ RECOMMENDED OPERATING CONDITIONS
Value
Parameter
Symbol
Condition
Unit
Min
7
Typ
Max
19
Power supply voltage
VCC
IREF
IVH
VCC, VCCO terminal
VREF terminal
12
V
mA
mA
V
Reference voltage output current
VH output current
−1
0
0
VH terminal
30
VINE
VDTC
VCTL
IO
−INE1, −INE2 terminal
DTC1, DTC2 terminal
CTL terminal
0
VCC − 0.9
VCC − 0.9
19
Input voltage
0
V
Control input voltage
Output current
0
V
OUT1, OUT2 terminal
Duty ≤ 5% (t = 1/fOSC×Duty)
−45
−450
+45
mA
mA
Output Peak current
IOP
+450
Overcurrent detection
by ON resistance of FET
100
500
1000
kHz
Oscillation frequency
fOSC
*
100
39
500
100
24
1500
560
130
1.0
kHz
pF
Timing capacitor
CT
RT
Timing resistor
11
kΩ
µF
µF
µF
VH terminal capacitor
Soft-start capacitor
Short-circuit detection capacitor
CVH
CS
VH terminal
0.1
0.1
0.1
CS1, CS2 terminal
CSCP terminal
1.0
CSCP
1.0
Reference voltage output
capacitor
CREF
Ta
VREF terminal
0.1
1.0
µF
°C
Operating ambient temperature
−30
+25
+85
* : See“ ■ SETTING THE TRIANGULAR OSCILLATION FREQUENCY”.
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
5