128 KByte Flash Module (S12FTMRC128K1V1)  
Table 13-39. Program P-Flash Command FCCOB Requirements  
CCOBIX[2:0]  
FCCOB Parameters  
011  
100  
Word 1 program value  
Word 2 program value  
Word 3 program value  
101  
1. Global address [2:0] must be 000  
Upon clearing CCIF to launch the Program P-Flash command, the Memory Controller will program the  
data words to the supplied global address and will then proceed to verify the data words read back as  
expected. The CCIF flag will set after the Program P-Flash operation has completed.  
Table 13-40. Program P-Flash Command Error Handling  
Register  
Error Bit  
Error Condition  
Set if CCOBIX[2:0] != 101 at command launch  
Set if command not available in current mode (see Table 13-27)  
Set if an invalid global address [17:0] is supplied  
ACCERR  
Set if a misaligned phrase address is supplied (global address [2:0] != 000)  
Set if the global address [17:0] points to a protected area  
Set if any errors have been encountered during the verify operation  
FSTAT  
FPVIOL  
MGSTAT1  
Set if any non-correctable errors have been encountered during the verify  
operation  
MGSTAT0  
13.4.5.6 Program Once Command  
The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the  
nonvolatile information register located in P-Flash. The Program Once reserved field can be read using the  
Read Once command as described in Section 13.4.5.4. The Program Once command must only be issued  
once since the nonvolatile information register in P-Flash cannot be erased. The Program Once command  
must not be executed from the Flash block containing the Program Once reserved field to avoid code  
runaway.  
Table 13-41. Program Once Command FCCOB Requirements  
CCOBIX[2:0]  
FCCOB Parameters  
Not Required  
000  
001  
010  
011  
100  
101  
0x07  
Program Once phrase index (0x0000 - 0x0007)  
Program Once word 0 value  
Program Once word 1 value  
Program Once word 2 value  
Program Once word 3 value  
S12P-Family Reference Manual, Rev. 1.13  