ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 4. Static Electrical Characteristics (continued)
Characteristics noted under conditions VBAT, -40°C ≤ TA ≤ 125°C unless otherwise noted. Typical values noted reflect the
approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER OUTPUT (CONTINUED)
V1 Output Current Limitation
V1 - 100 mV
130
170
200
mA
I1MAX
NOM
V1 Overtemperature Shut OFF Threshold
Junction Temperature
160
130
20
—
—
—
190
160
40
°C
°C
TV1H
TV1L
V1 Pre-Warning Temperature Threshold
Junction Temperature
V1 Temperature Threshold Difference
V1 Reset Threshold on V1
°C
V
TV1H-TV1L
VR1
5.5 V < V
< 27 V
(C Version)
(D Version)
4.1
4.3
4.8
BAT
V2 - 0.4
V1 - 0.28
V1 - 0.1
V1 Reset Active V1 Range
1.0
—
—
V
V1R
VR1
—
V1 Reverse Current from V1 to V
and GND
1.0
mA
BAT
IREV
V1 = 4.9 V, 0 < V
< 4.9 V
BAT
V2 Output Voltage
4.75
—
5.0
0.2
5.25
0.5
V
V
V2NOM
0 mA < I
< 200 mA 5.5 V < V
< 40 V
BAT
OUT
V2 Drop Voltage
= 200 mA (7)
V2DROP
I
OUT
V2 Drop Voltage
= 20 mA (7)
—
0.05
0.15
V
V2DROP
I
OUT
V2 Output Current Limitation
V2 -100 mV
I1
220
4.1
280
350
mA
V
MAX
NOM
V2 Threshold on V2 to Report V2 OFF
V2 Nominal
V
4.55
4.75
R2
V
Delay Time
µs
°C
V
20
—
—
70
R2
R2
V2 Overtemperature Pre-Warning Threshold
V2 Junction Temperature
T
130
160
V2L
V2 Overtemperature Switch-OFF Threshold
V2 Junction Temperature
°C
T
155
-15
—
—
185
+15
V2H
V2 Line Regulation
mV
V2LR1
V2LR2
V2LRR
9.0 V < V
< 16.5
BAT
V2 Load Regulation
4.0 mA < I < 200 mA
mV
dB
-75
30
—
+75
—
LOAD
V2 Line Ripple Rejection
100 Hz, 1.0 V on V
55
(8)
PP
BAT
Notes
7. Measured when V1 has dropped 100mV below its nominal value
8. Guaranteed by design; however, it is not production tested
33389
Analog Integrated Circuit Device Data
Freescale Semiconductor
9