ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 3. Static Electrical Characteristics (continued)
Characteristics noted under conditions 4.75 V ≤ VDD ≤ 5.25 V, 9.0 V ≤ VPWR ≤ 17 V, -40 °C ≤ TA ≤ 125 °C, unless otherwise
noted.
Characteristic
Symbol
Min
Typ
Max
Unit
DIGITAL INTERFACE
SI Logic High
SIV
SIV
4.0
–
–
–
–
–
–
–
–
2.0
–
V
V
IH
IL
SI Logic Low
CS and SCLK Logic High
CS and SCLK Logic Low
Input Logic High
CSV
CSV
3.0
–
V
IH
IL
3.0
–
V
V
V
3.15
–
V
IH
IL
Input Logic Low
1.35
V
Input Pull-down Current (25)
VIN = 1.5 V
I
I
μA
IN(PD)
5.0
-25
3.5
0
–
–
–
–
25
-5.0
–
Input Pull-up Current (26)
VIN = 3.5 V
μA
V
IN(PU)
SO and High-state Output Voltage
IOH = -1.0 mA
V
V
I
SOH
SOL
SO and Low-state Output Voltage
IOL = 1.0 mA
V
0.4
SO and Tri-state Leakage Current
CS = 0.7 VDD, VSO = 0.3 VDD
CS = 0.7 VDD, VSO = 0.7 VDD
μA
SOT
-10
–
–
–
–
10
Input Capacitance (27)
0 = VIN = 5.5 V
C
pF
pF
IN
–
–
–
–
12
20
SO and Tri-state Capacitance (28)
0 = VIN = 5.5 V
C
SOT
Notes
18. Outputs of device functionally turn-on (RDS(ON) = 0.95 Ω @125 °C). SPI/parallel inputs and power outputs are operational. Fault
detection and reporting may not be fully operational within this range.
19. Value reflects all outputs ON and equally conducting 1.0 A each. V
= 5.5 V, CS = 5.0 V.
PWR
20. An over-voltage condition will cause any enabled outputs to latch OFF (disabled).
21. This parameter is guaranteed by design; however, it is not production tested.
22. For VDD less than the Power-ON Reset voltage, all outputs are disabled and the serial fault register is reset to all 0s.
23. Drain current per output with VPWR = 24 V and VLOAD = 9.0 V.
24. Drain current per output with V
= 13 V, VLOAD = 9.0 V.
PWR
25. Inputs SI, IN0 & IN1, IN2 & IN3, IN4 & IN5, and IN0 to IN7 incorporate active internal pull-down current sinks for noise immunity
enhancement.
26. The MODE and CS inputs incorporate active internal pull-up current sources for noise immunity enhancement.
27. This parameter applies to inputs SI, CS, SCLK, MODE, IN0 & IN1, IN2 & IN3, IN4 & IN5, and IN0 to IN7. It is guaranteed by design;
however, it is not production tested.
28. This parameter applies to the OFF state (tri-stated) condition of SO and is guaranteed by design; however, it is not production tested.
33882
Analog Integrated Circuit Device Data
Freescale Semiconductor
8