欢迎访问ic37.com |
会员登录 免费注册
发布采购

33800 参数 Datasheet PDF下载

33800图片预览
型号: 33800
PDF下载: 下载PDF文件 查看货源
内容描述: 发动机控制集成电路 [Engine Control Integrated Circuit]
分类和应用:
文件页数/大小: 39 页 / 1879 K
品牌: FREESCALE [ Freescale ]
 浏览型号33800的Datasheet PDF文件第22页浏览型号33800的Datasheet PDF文件第23页浏览型号33800的Datasheet PDF文件第24页浏览型号33800的Datasheet PDF文件第25页浏览型号33800的Datasheet PDF文件第27页浏览型号33800的Datasheet PDF文件第28页浏览型号33800的Datasheet PDF文件第29页浏览型号33800的Datasheet PDF文件第30页  
FUNCTIONAL DEVICE OPERATION  
LOGIC COMMANDS AND REGISTERS  
temperature of the output driver to determine the fault. Both  
methods may be selected or used individually. The following  
table provides an explanation of operation during fault  
condition.  
PARALLEL OUTPUT, PX PIN ENABLE COMMAND  
The Parallel Output command allows the user to parallel  
output for increased current capability and enables control of  
the PX input pin.  
The low duty cycle used for the timer protection scheme is  
set by the fault timer used to detect the short circuit. For short  
circuits detected based on the output voltage exceeding the  
fault detection voltage threshold, the outputs will be turned off  
for the duration of the refresh timer (typically 10ms) and  
turned on for the duration of the on-state short circuit fault  
timer (typically 500µs). For short circuits detected based on  
the output current exceeding the output current limit, the  
outputs will be turned off for the duration of the refresh timer  
(typically 10 ms) and turned on for the duration of the current  
limit fault timer (typically 50µs).  
A logic 0 in the Parallel Output Command provides  
individual control. Logic 1 commands outputs to operate in  
parallel. For example, with bit 4 in the Parallel Output  
command a logic 1, outputs 1 & 2 are controlled together  
With the outputs paralleled, and the P1 pin enabled, a logic  
1 on SPI bit 0 or SPI bit 1 will command both outputs on.  
Similarly a logic 1 on the P1 pin will command both outputs  
on.  
PX pin Enable bit 0 through bit 3 enables or disables the  
P1, P3, P5, P7 pins respectively. A logic 0 in the SPI word will  
enable the PX input pin, while logic 1 in the SPI word will  
disable the PX input pin. Default state is with the PX input  
pins enabled.  
For off-state open load faults with retry timer enabled, the  
off-open fault is released and re-detected every 1-2 retry  
timer periods. Retry timer for 1-2, 3-4, 5-6, and 7-8 are out of  
phase and may report a load present, if the OSS read  
command CS is issued after the release, and before the re-  
detection (~500µs) of the off-state open load fault.  
When paralleling output 1 & 2 the current limit is  
maintained at 4.0 to 6.0A. Parallel current limit for drivers  
3&4, 5&6, 7&8 is increased to a range of 2.0 to 4.0A.  
Using a MOSFET as output switches allows the  
connection of paired outputs. The RDS(ON) of MOSFET  
devices have inherent positive temperature coefficient  
providing balanced current sharing between outputs without  
destructive operation. This mode of operation may be  
desirable in the event the application requires lower power  
dissipation or the added capability of switching higher  
currents. Performance of parallel operation results in a  
corresponding decrease in RDS(ON), while the Output Current  
Limit increases correspondingly. Output OFF Open Load  
Detect current may increase based on how the Output OFF  
Open Load Detect is programmed.  
Table 13. TLim/Timer Control  
Fault  
Timer  
Bit  
Shutdn  
Retry Bit  
TLIM  
Bit  
Operation During Short Fault  
Timer only, Outputs will retry on  
period  
1
0
X
OUT1-8 = ~500us for short  
circuit faults, and 50us for current  
limit faults ON, ~10ms OFF.  
TLim only, Outputs will retry on  
TLim hysteresis.  
1
1
1
1
0
1
Table 14. And/Or/SPI/Parallel Control  
Timer and TLim, Outputs will  
retry on period and driver  
temperature below threshold.  
Parallel PX Pin  
AND/  
OR Bit Bit 1  
SPI  
SPI  
Bit 0  
Output  
1&2  
PX Pin  
En Bit  
En Bit  
OUT1-8 = ~500us ON, ~10ms  
OFF  
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
1
1
1
1
1
X
X
X
X
0
0
0
0
0
X
1
1
1
X
0
0
1
1
0
0
1
1
X
0
0
1
1
0
1
0
1
0
1
0
1
X
0
1
0
1
OFF  
ON  
X
Timer only, Outputs will not retry  
on period  
0
0
X
X
ON  
OUT1-8 = ~500us ON, OFF  
X
ON  
TLim only, Outputs will not retry  
on TLim hysteresis.  
0
0
1
1
0
1
1(or)  
1(or)  
1(or)  
1(or)  
0(and)  
0(and)  
0(and)  
0(and)  
0(and)  
OFF  
ON  
Timer and TLim, Outputs will not  
retry on period or TLim.  
ON  
OUT1-8 = ~500us ON, OFF  
ON  
All OSS outputs have a current limit control loop. Current  
limit is always active in Normal Mode. Current limit for OUT1  
and OUT2 is 4.0 to 6.0A. Current limit for OUT3 through  
OUT8 is 1.0 to 2.0A.  
OFF  
OFF  
ON  
ON  
ON  
33800  
Analog Integrated Circuit Device Data  
Freescale Semiconductor  
26  
 复制成功!