FUNCTIONAL DEVICE OPERATION  
SUPPLIES  
Table 47. Buck Switchers (SW1, 2, 3, 4) Output Voltage Programmability  
Set point  
29  
SWx[4:0]  
SWx Output, SWxHI = 0 (Volts)  
SWx Output (59), SWxHI = 1 (Volts)  
11101  
11110  
11111  
1.325  
1.350  
1.375  
1.825  
1.850  
1.850  
30  
31  
59. Output range not available for SW1. SW1 output range is 0.600-1.375, therefore SW1HI = 1 does not apply to SW1. The SW1HI bit  
should always be set to 0.  
Since the startup default values of the buck switchers are dependent on the state of the PUMS pin, the SWxHI bit settings will  
likewise be determined by the PUMS pin. The settings are aligned to the likely application ranges for use cases as given in the  
Defaults tables in Power Control System. The following tables define the SWxHI bit states after a startup event is completed, but  
can be reconfigured via the SPI if desired, if an alternate range is needed. Care should be taken when changing SWxHI bit to  
avoid unintended jumps in the switcher output. The SWxHI setting applies to Normal, Standby, and DVS set points for the  
corresponding switcher.  
Table 48. SWxHI States for Power Up Defaults  
PUMS1  
PUMS2  
SW1HI  
SW2HI  
SW3HI  
SW4HI  
Ground  
Open  
VCOREDIG  
VCORE  
Ground  
Open  
Open  
Open  
Open  
Open  
Ground  
Ground  
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
0
1
1
1
0
1
1
1
Note that the following efficiency curves were measured with the MC13892 in a socket.  
13892  
Analog Integrated Circuit Device Data  
Freescale Semiconductor  
75  