ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 5. Static Electrical Characteristics
Characteristics noted under conditions -40°C ≤ TA ≤ 85 °C, GND = 0 V unless otherwise noted. Typical values noted reflect
the approximate parameter means at TA = 25 °C under nominal conditions, unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
VSRTC ACTIVE MODE – DC
Output Voltage VOUT
VSRTC
V
VINMIN < VIN < VINMAX, ILMIN < IL < ILMAX
1.15
0
1.20
-
1.25
CLK AND MISO
Input Low CS, MOSI, CLK
VINCSLO
VINMOSILO
VINCLKLO
0.3*SPIVCC
V
V
Input High CS, MOSI, CLK
VINCSHI
VINMOSIHI
VINCLKHI
0.7*SPIVCC
-
-
SPIVCC+0.3
0.2
Output Low MISO, INT
Output sink 100 µA
VOMISOLO
VOINTLO
V
V
0
Output High MISO, INT
Output source 100 µA
VOMISOHI
VOINTHI
SPIVCC-0.2
1.75
-
-
SPIVCC
3.1
SPIVCC Operating Range
BUCK CONVERTERS
Operating Input Voltage
SPIVCC
V
V
VSWIN
PWM operation, 0 < IL < IMAX
PFM operation, 0 < IL < IMAX
Extended PWM or PFM operation(13)
3.0
2.8
UVDET
-
-
-
4.65
4.65
4.65
Output Voltage Range
Switcher 1
VSW1
V
0.6
0.6
-
-
1.375
1.850
Switchers 2, 3, and 4
Output Accuracy
mV
mA
PWM mode including ripple, load regulation, and transients (14)
PFM Mode, including ripple, load regulation, and transients
VSWLOPP
VSWLIPPI
Nom-50
Nom-50
Nom
Nom
Nom+50
Nom+50
Maximum Continuous Load Current, IMAX, VINMIN<BP<4.65 V
SW1 in PWM mode (SWILIMB = 0, no max current limit)
-
ISW1
800
1050
800
800
-
-
SW1 in PWM Mode (SWILIMB = 1, no max current limit)(15)
SW2, SW3, SW4 in PWM mode (SWILIMB = 0, no max current limit)
SW2, SW3, SW4 in PWM mode (SWILIMB = 1, no max current limit)(15)
SW1, SW2, SW3, SW4 in PFM mode
ISW2,3,4
ISW2,3,4
ISW1, 2, 3, 4
-
-
50
-
-
-
Maximum Peak Load Current, IPEAK, BP ≤ 4.2 V,
mA
ISW1
ISW4
1250
1000
-
-
-
-
SW1 in PWM Mode (SWILIMB = 1, no max current limit)(15)
SW4 in PWM Mode (SWILIMB = 1, no max current limit)(15)
Notes
13. In the extended operating range the performance may be degraded
14. Transient loading for load steps of ILmax/2
15. In this mode, current limit protection is disabled for SW1 - SW4 by setting SWILIMB = 1. Therefore, the load on SW1-4 should not exceed
the conditions specified in the table above. Application needs to provide current limit protection circuitry either in battery or as pre-
regulated supply to BP.
13892
Analog Integrated Circuit Device Data
Freescale Semiconductor
13