FUNCTIONAL DEVICE OPERATION  
OPERATIONAL MODES  
OPERATIONAL MODES  
The 10XS3412 has four operating modes: Sleep, Normal,  
Fail-safe and Fault. Table 6 and Figure 11 summarize details  
contained in succeeding paragraphs.  
• fault = OC[0:3] or OT[0:3] or SC[0:3] or UV or (OV and  
OV_dis).  
Table 6. 10XS3412 Operating Modes  
The Figure 10 describes an internal signal called IN_ON[x]  
depending on IN[x] input.  
Mode wake-up fail fault  
Comments  
Sleep  
0
1
x
x
Device is in Sleep mode. All  
outputs are OFF.  
tIN  
Normal  
0
0
Device is currently in Normal  
mode. Watchdog is active if  
enabled.  
IN[x]  
IN_ON[x]  
Fail Safe  
1
1
0
1
Device is currently in Fail-safe  
mode due to watchdog  
timeout or VDD Failure  
conditions. The output states  
depend on the corresponding  
input in case the FSI is open.  
Figure 10. IN_ON[x] internal signal  
The 10XS3412 transits to operating modes according to  
the following signals:  
Fault  
1
X
Device is currently in Fault  
mode. The faulted output(s) is  
(are) OFF. The safe autoretry  
circuitry is active to turn-on  
again the output(s).  
• wake-up = RST or WAKE or IN_ON[0] or IN_ON[1] or  
IN_ON[2] or IN_ON[3],  
• fail = (VDD Failure and VDD_FAIL_en) or (Watchdog  
timeout and FSI input not shorted to ground),  
x = Don’t care.  
(fail=0) and (wake-up=1) and (fault=0)  
(wake-up=0)  
Sleep  
(wake-up=0)  
(wake-up=1) and  
(fail=1)  
and (fault=0)  
(wake-up=1)  
and (fault=1)  
(wake-up=0)  
(fail=1) and  
(wake-up=1)  
and (fault=1)  
(fail=0) and  
(wake-up=1)  
and (fault=1)  
Fault  
Normal  
(fail=0) and  
(wake-up=1)  
and (fault=0)  
(fail=1) and  
(wake-up=1)  
and (fault=0)  
Fail Safe  
(fail=0) and (wake-up=1) and (fault=0)  
(fail=1) and (wake-up=1) and (fault=0)  
Figure 11. Operating Modes  