欢迎访问ic37.com |
会员登录 免费注册
发布采购

F81867D-I 参数 Datasheet PDF下载

F81867D-I图片预览
型号: F81867D-I
PDF下载: 下载PDF文件 查看货源
内容描述: 6个UART μSuper IO 128字节FIFO和省电功能 [6 UARTs μSuper IO With 128 Bytes FIFO and Power Saving Functions]
分类和应用: 先进先出芯片
文件页数/大小: 315 页 / 2394 K
品牌: FINTEK [ FEATURE INTEGRATION TECHNOLOGY INC. ]
 浏览型号F81867D-I的Datasheet PDF文件第75页浏览型号F81867D-I的Datasheet PDF文件第76页浏览型号F81867D-I的Datasheet PDF文件第77页浏览型号F81867D-I的Datasheet PDF文件第78页浏览型号F81867D-I的Datasheet PDF文件第80页浏览型号F81867D-I的Datasheet PDF文件第81页浏览型号F81867D-I的Datasheet PDF文件第82页浏览型号F81867D-I的Datasheet PDF文件第83页  
F81867  
RPM mode(CR96 bit2=0):  
FAN2 expect speed count value (MSB), in auto fan mode(CR96  
bit3Î0) this register is auto updated by hardware.  
Duty mode (CR96 bit2=1):  
B2h  
R/W  
VBAT  
8’h00  
This byte is reserved byte.  
RPM mode(CR96 bit2=0):  
FAN2 expect speed count value (LSB) or expect PWM duty , in auto  
fan mode this register is auto updated by hardware and read only.  
Duty mode(CR96 bit2=1):  
B3h  
R/W  
VBAT  
8’h01  
The Value programming in this byte is duty value. In auto fan mode  
(CR96 bit3Î0) this register is updated by hardware.  
Ex: 5Î 5*100/255 %  
255 Î 100%  
FAN2 full speed count reading (MSB). At the moment of reading this  
register, the LSB will be latched. This will prevent from data updating  
when reading. To read the fan count correctly, read MSB first and  
followed read the LSB.  
B4h  
B5h  
R/W  
R/W  
5VSB  
5VSB  
8’h03  
8’hff  
FAN2 full speed count reading (LSB).  
VT2 BOUNDARY 1 TEMPERATURE – Index B6h  
Bit  
Name  
R/W Reset Default  
Description  
The first boundary temperature for VT2 in temperature mode.  
When VT2 temperature exceeds this boundary, FAN2 expect value will  
load from segment 1 register (index Bah).  
3Ch  
(60oC)  
7-0  
BOUND1TMP2  
R/W  
5VSB  
When VT2 temperature is under this boundary – hysteresis, FAN2 expect  
value will load from segment 2 register (index BAh).  
This byte is a 2’s complement value ranging from -128ºC ~ 127ºC.  
VT2 BOUNDARY 2 TEMPERATURE – Index B7  
Bit  
Name  
R/W Reset Default  
Description  
The 2nd BOUNDARY temperature for VT2 in temperature mode.  
When VT2 temperature is exceed this boundary, FAN2 expected value  
will load from segment 2 register (index BBh).  
When VT2 temperature is below this boundary – hysteresis, FAN2  
expected value will load from segment 3 register (index BCh).  
This byte is a 2’s complement value ranging from -128ºC ~ 127ºC.  
32  
R/W 5VSB  
(50ºC)  
7-0  
BOUND2TMP2  
79  
Dec, 2011  
V0.12P  
 复制成功!