a. Once temp. is under 40°C, the lowest fan speed keeps 50% PWM duty  
b. Once temp. is over 40°C,60°C, the fan speed will vary from 70% to 100% PWM duty  
and increase with temp. level.  
c. Once temp. keeps in 55°C, fan speed keeps in 70% PWM duty  
d. If set the hysteresis as 3°C (default 4°C), once temp reduces under 57°C, fan speed  
reduces to 70% PWM duty and stays there.  
Linear auto mode  
Otherwise, F71862 supports linear auto mode. Below has a example to describe this  
mode. More detail, please refer the register description.  
A. Linear auto mode (PWM Duty I)  
Set temperature as 70°C, 40°C and Duty as 100%, 70%, 40%  
PWM duty  
100%  
70 Degree C  
hysteresis 65 Degree C  
70%  
40 Degree C  
40%  
Temp.  
Fan Speed  
a
b
c
d
a. Once temp. is under 40°C, the lowest fan speed keeps 40% PWM duty  
b. Once temp. is over 40°C and under 70°C, the fan speed will vary from 40% to 70%  
PWM duty and linearly increase with temp. variation. The temp.-fan speed monitoring  
and flash interval is 1sec.  
c. Once temp. goes over 70°C, fan speed will directly increase to 100% PWM duty (full  
speed)  
d. If set the hysteresis as 5°C(default is 4°C), once temp reduces under 65°C (not 70°C),  
fan speed reduces from 100% PWM duty and decrease linearly with temp..  
FAN_FAULT#  
Fan_Fault# will be asserted when the fan speed doesn’t meet the expected fan speed  
within a programmable period (default is 11 seconds) or when fan stops with respect to  
PWM duty-cycle which should be able to turn on the fan. There are two conditions may  
48  