F71862  
A2h  
A3h  
-
-
Reserved  
The Value programming in this byte is duty value. In auto fan mode(CR96  
bit5Î0) this register is updated by hardware.  
Ex: 5Î 5*100/255 %  
R/W  
8’h01  
255 Æ 100%  
FAN1 full speed count reading (MSB). At the moment of reading this register, the LSB  
will be latched. This will prevent from data updating when reading. To read the fan  
count correctly, read MSB first and followed read the LSB.  
FAN1 full speed count reading (LSB).  
A4h  
A5h  
R/W  
R/W  
8’h03  
8’hff  
VT1 BOUNDARY 1 TEMPERATURE – Index A6h  
Bit  
7
Name  
R/W Default  
Description  
Return 0 when read.  
Reserved  
RO  
0
The 1st BOUNDARY temperature for VT1 in temperature mode.  
When VT1 temperature is exceed this boundary, FAN1 expect value will  
load full speed duty 8’hFF.  
3Ch  
(60oC)  
6-0  
BOUND1TMP1  
R/W  
When VT1 temperature is below this boundary – hysteresis, FAN1 expect  
value will load from segment 1 register (index ABh).  
VT1 BOUNDARY 2 TEMPERATURE – Index A9  
Bit  
Name  
R/W Default  
Description  
Return 0 when read.  
7
Reserved  
RO  
0
The 2st BOUNDARY temperature for VT1 in temperature mode.  
When VT1 temperature is exceed this boundary, FAN1 expect value will  
load from segment 1 register (index ABh).  
1Eh  
(30oC)  
6-0  
BOUND4TMP1  
R/W  
When VT1 temperature is below this boundary – hysteresis, FAN1 expect  
value will load from segment 2 register (index AEh).  
FAN1 SEGMENT 1 SPEED COUNT – Index ABh  
Bit  
Name  
R/W Default  
Description  
The value that set in this byte is mean the expect PWM duty-cycle in this  
temperature section.  
D9h  
R/W  
7-0  
SEC1SPEED1  
(85%)  
FAN1 SEGMENT 2 SPEED COUNT  
– Index AEh  
Bit  
Name  
R/W Default  
Description  
The value that set in this byte is mean the expect PWM duty-cycle in this  
temperature section.  
80h  
R/W  
7-0  
SEC2SPEED1  
(50%)  
FAN1 Temperature Mapping Select – Index AFh  
Bit  
7-6  
5
Name  
Reserved  
R/W Default  
Description  
Reserved  
--  
0
0
0
Set 1 to force FAN1 to full speed if any temperature over its high limit.  
Set 1 will enable the interpolation of the fan expect table.  
FAN1_UP_T_EN  
FAN1_INTERPOLATION_  
EN  
R/W  
4
R/W  
This register controls the FAN1 duty movement when temperature over  
highest boundary.  
0: The FAN1 duty will increases with the slope selected by  
FAN1_RATE_SEL register (Index 9Bh).  
1: The FAN1 duty will directly jumps to full speed.  
1
3
FAN1_JUMP_HIGH_EN R/W  
59  