Feature Integration Technology Inc.
Fintek
F15353
Day of week data (00 to 06)
W4
A septenary counter. Set it so that it corresponds to the day of the week.
H4
m4
s4
Refer to bit 4.
Y2
M2
D2
W2
H2
1
R
-
Refer to bit 2
m2
s2
Y1
M1
D1
W1
H1
m1
s1
0
R
-
Refer to bit 2
7.4Real-time Data 2 Access, Hour Data (Command 011b)
Bit
Name
R/W Default
Description
7
-
-
-
Reserved
For a 12-hour expression, write 0 and 1 for AM and PM, respectively. For a
24-hour expression, either 0 or 1 can be written. 0 is read when the hour
data is from 00 to 11, and 1 is read when from 12 to 23.
Minute data (00 to 59)
AMPM
6
m40
s40
Second data (0 to 59).
H20
m20
s20
Hour data (00 to 23 or 00 to 11)
5
4
R/W
R/W
-
-
Refer to bit 6.
Refer to bit 5.
H10
m10
s10
V0.12P