FTR-1621-XX WDM GBIC
Product Specification - March 2002
Finisar
VI. General Specifications
General
Units Notes/Conditions
Gb/sec Fibre Channel, IEEE 802.3,
SONET OC-3/12/48 Compatible
Total System Budget
--
27
31
dB @2.5 Gb/s, BER <10
-12
w/PRBS
2
-23
-1. See Note 1
Note 1: Total system budget is defined as P
out
– P
in
– typical connector losses
Table 7. General specifications
Parameter
Data Rate
Symbol Min
BR 0.125
Typ
Max
2.7
VII. Environmental Specifications
Note that the GBIC Specification requires an ambient temperature range of 0 to +50°C.
Finisar FTR-1621-XX GBICs have an extended range from 0°C to +60°C case
temperature as specified in Table 8.
Environment
Units Notes/Conditions
°C Case temperature
°C
CDRH and IEC-825 Class 1 Laser Product
Note 1
Note 1: Complies with FDA performance standards for laser products except for deviations pursuant to
Laser Notice No. 50, dated July 26, 2001.
Table 8. Environmental specifications
Parameter
Operating Temp
Storage Temp
Eye Safety
Symbol
T
op
T
sto
--
Min
0
-10
Typ
Max
60
85
© Finisar Corporation 01-Mar-02 Rev.F
Page 6