欢迎访问ic37.com |
会员登录 免费注册
发布采购

MP3276AG 参数 Datasheet PDF下载

MP3276AG图片预览
型号: MP3276AG
PDF下载: 下载PDF文件 查看货源
内容描述: 故障保护16通道, 12位数据采集子系统 [Fault Protected 16 Channel, 12-Bit Data Acquisition Subsystem]
分类和应用: 转换器模数转换器信息通信管理
文件页数/大小: 16 页 / 172 K
品牌: EXAR [ EXAR CORPORATION ]
 浏览型号MP3276AG的Datasheet PDF文件第5页浏览型号MP3276AG的Datasheet PDF文件第6页浏览型号MP3276AG的Datasheet PDF文件第7页浏览型号MP3276AG的Datasheet PDF文件第8页浏览型号MP3276AG的Datasheet PDF文件第10页浏览型号MP3276AG的Datasheet PDF文件第11页浏览型号MP3276AG的Datasheet PDF文件第12页浏览型号MP3276AG的Datasheet PDF文件第13页  
MP3276
+5 V
3k
+5 V
3k
DB
N
DB
N
3k
DB
N
C
L
3k
10pF
DB
N
C
L
10pF
a. High-Z to V
ON
b. High-Z to V
OL
a. V
ON
to High-Z
b. V
OL
to High-Z
Figure 3. Load Circuit for Data
Access Time Test
Figure 4. Load Circuit for
Bus Relinquish Time Test
STL, STS
C
L
DGND
Figure 5. Load Circuit for WR to STS Delay
Serial Data Output Mode (PXS = 0)
The MP3276 output data is available in serial form when PXS
= 0 prior to the RD high-to-low transition. When PXS = 0, the
DB11/SDO pin functions as the serial data output. The
DB0/SDC pin functions as the serial clock input and all other
data outputs are 3-stated.
The serial data output sequence is MSB (DB11) first to LSB
(DB0) last. The MSB (DB11) data bit appears at DB11/SDO
when STS goes low. The second most significant bit appears at
DB11/SDO on the next DB0/SDC high-to-low transition. The
LSB (DB0) is present at DB11/SDO on the 11th SDC high-to-low
transition.
The control pin functions (ADEN, CS, WR, and RD) are the
same as the parallel mode of operation. Further information re-
garding serial control and timing is shown in
Figure 6., Table 4.
and
Table 5.
For a minimum interconnect serial environment, the channel
address state can be generated in at least two ways, using an
address counter, or using an address serial to parallel converter.
WR can then be used as the counter clock or shift register load
signal as well as the A/D converter start convert signal on the ris-
ing edge. (Note that the falling edge loads the address present at
the address port.)
STS
t
21
t
22
SDC
DB11/SDO
SDC should be in a high state during the STS high period. SDC can make the first high to low transition after t
21
. In normal use it is
assumed that PXS is hardwired low. However, if the mode of operation is changed, PXS must go low prior to RD going low.
Rev. 4.00
9
ÇÇÇÇÇ
ÇÇÇÇÇ
See Table 4
t
20
DB10
DB11 (MSB)