PT67-21C/L41/TR8
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO. Item
Test Conditions
Test Hours/ Sample Failure
Ac/Re
Cycles
Sizes
22pcs
22pcs
Judgement
Criteria
TEMP.:240℃± 5℃
1 REFLOW
6Mins
0/1
0/1
5secs
I
C(ON)≦L× 0.8
H : +85℃
30mins
2 Temperature Cycle
50Cycles
5mins
L:Lower
Specification
Limit
L : -55℃
30mins
H :+100℃
5mins
3 Thermal Shock
50Cycles
22pcs
0/1
10secs
5mins
L :-10℃
TEMP.:+100℃
4 High Temperature
Storage
1000hrs
1000hrs
22pcs
22pcs
0/1
0/1
TEMP.:-55℃
5 Low Temperature
Storage
6 DC Operating Life VCE=5V
1000hrs
1000hrs
22pcs
22pcs
0/1
0/1
85℃ / 85% R.H
7 High Temperature/
High Humidity
Everlight Electronics Co., Ltd.
http:\\www.everlight.com
Rev 1.1
Page: 9 of 10
Device No:DTT-067-038
Prepared date:05-02-2003
Prepared by:Jaine Tsai