 浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第2页浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第3页浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第4页浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第5页浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第7页浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第8页浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第9页浏览型号EM638325TS-5.5/-5.5G的Datasheet PDF文件第10页  
EtronTech
Commands
1
2Mega x 32 SDRAM
EM638325
BankActivate
(RAS# = "L", CAS# = "H", WE# = "H", BS = Bank, A0-A10 = Row Address)
The BankActivate command activates the idle bank designated by the BS0,1 (Bank Select)
signal. By latching the row address on A0 to A10 at the time of this command, the selected row
access is initiated. The read or write operation in the same bank can occur after a time delay of
t
RCD
(min.) from the time of bank activation. A subsequent BankActivate command to a different row
in the same bank can only be issued after the previous active row has been precharged (refer to the
following figure). The minimum time interval between successive BankActivate commands to the
same bank is defined by t
RC
(min.). The SDRAM has four internal banks on the same chip and shares
part of the internal circuitry to reduce chip area; therefore it restricts the back-to-back activation of
the four banks. t
RRD
(min.) specifies the minimum time required between activating different banks.
After this command is used, the Write command and the Block Write command perform the no mask
write operation.
T0
T1
T2
T3
..............
Bank A
Row Addr.
RAS# - CAS# delay (
t
RCD
)
Bank A
Col Addr.
..............
Bank B
Row Addr.
RAS# - RAS# delay time (
t
RRD
)
R/W A with
AutoPrecharge
Tn+3
Tn+4
Tn+5
Tn+6
CLK
ADDRESS
Bank A
Row Addr.
COM MAND
Bank A
Activate
NOP
NOP
..............
Bank B
Activate
NOP
NOP
Bank A
Activate
RAS# Cycle time (
t
RC
)
AutoPrecharge
Begin
: "H" or "L"
BankActivate Command Cycle (Burst Length = n, CAS# Latency = 3)
2
BankPrecharge command
(RAS# = "L", CAS# = "H", WE# = "L", BS = Bank, A10 = "L", A0-A9 = Don't care)
The BankPrecharge command precharges the bank disignated by BS0,1 signal. The
precharged bank is switched from the active state to the idle state. This command can be asserted
anytime after t
RAS
(min.) is satisfied from the BankActivate command in the desired bank. The
maximum time any bank can be active is specified by t
RAS
(max.). Therefore, the precharge function
must be performed in any active bank within t
RAS
(max.). At the end of precharge, the precharged
bank is still in the idle state and is ready to be activated again.
PrechargeAll command
(RAS# = "L", CAS# = "H", WE# = "L", BS = Don’t care, A10 = "H", A0-A9 = Don't care)
The PrechargeAll command precharges all the four banks simultaneously and can be issued
even if all banks are not in the active state. All banks are then switched to the idle state.
Read command
(RAS# = "H", CAS# = "L", WE# = "H", BS = Bank, A10 = "L", A0-A7 = Column Address)
The Read command is used to read a burst of data on consecutive clock cycles from an active
row in an active bank. The bank must be active for at least t
RCD
(min.) before the Read command is
issued. During read bursts, the valid data-out element from the starting column address will be
available following the CAS# latency after the issue of the Read command. Each subsequent data-
out element will be valid by the next positive clock edge (refer to the following figure). The DQs go
into high-impedance at the end of the burst unless other command is initiated. The burst length,
burst sequence, and CAS# latency are determined by the mode register which is already
programmed. A full-page burst will continue until terminated (at the end of the page it will wrap to
column 0 and continue).
3
4
Preliminary
6
Rev 1.4
Oct. 2005