欢迎访问ic37.com |
会员登录 免费注册
发布采购

P3356 参数 Datasheet PDF下载

P3356图片预览
型号: P3356
PDF下载: 下载PDF文件 查看货源
内容描述: 低失真线路匹配变压器 [LOW DISTORTION LINE MATCHING TRANSFORMER]
分类和应用: 变压器配套器件
文件页数/大小: 6 页 / 191 K
品牌: ETAL [ ETAL Group ]
 浏览型号P3356的Datasheet PDF文件第1页浏览型号P3356的Datasheet PDF文件第2页浏览型号P3356的Datasheet PDF文件第3页浏览型号P3356的Datasheet PDF文件第4页浏览型号P3356的Datasheet PDF文件第6页  
P3356  
ENVIRONMENTAL TESTING  
Reliability testing to IEC 68  
Tested to clauses of IEC 68 and compliant with all functional and safety requirements following exposure as follows:  
Test description IEC 68 reference  
Test details  
Result  
Robustness of 68-2-21 Test Ua1  
Tensile 5N pull  
Thrust 1N push  
No impairment  
No pin detachment or distortion  
terminations  
Solderability  
68-2-21 Test Ua2  
68-2-20 Test Ta Method 1 Solder bath 235ºC 2s  
No impairment  
Finish smooth, bright and even  
Resistance to  
soldering heat  
68-2-20 Test Tb Method 1A Solder bath 260ºC 10s  
68-2-20 Test Tb Method 2 Soldering iron 350ºC 5s  
Vibration  
68-2-6 Test Fc  
Sweep 10-55-10Hz in 1 minute  
Amplitude 1.5mm pk-pk  
Duration 2h per axis, 3 axes  
No impairment  
No impairment  
Shock  
68-2-27 Test Ea  
Peak acceleration 1000m/s2  
Duration of pulse 6ms  
3 shocks each direction on 3 axes  
Cold  
68-2-1 Test Ab  
68-2-2 Test Bb  
68-2-3 Test Ca  
68-2-14 Test Na  
-25ºC 16h  
Recovery to ambient 1-2h  
No impairment  
No impairment  
No impairment  
No impairment  
Dry heat  
Damp heat  
125ºC 16h  
Recovery to ambient 1-2h  
40ºC 4 days, RH 93%  
Recovery to ambient 1-2h  
Change of  
TA –25ºC  
temperature  
TB +85ºC  
t1 30 min  
2 min t23 min  
Recovery to ambient 1-2h  
5 cycles  
Combined Environmental Reliability Testing (CERT)  
Components step stressed at increasing levels of severity using combined stresses to detect potential  
weaknesses.  
Results are shown for highest levels of stress tested. Compliant with all functional and safety tests following  
exposure as follows:  
Test description  
Test details  
Duration  
Result  
Storage Test  
Thermal cycling -30ºC to +100ºC at  
11ºC/min  
20 mins per  
plane  
No impairment  
6mm pk 2-9Hz at 1 octave/min  
20m/s2 9-200Hz  
Transportation Test Thermal cycling -65ºC to +80ºC  
Random vibration 10-200Hz and  
2 hours per  
plane  
No impairment  
200-2000Hz at 57m/s2 RMS  
ETALDOC 591/11  
Page 5 of 6  
December 2005