P3356
Improved matching and hybrid
European CTR21/(Australia, etc.)
Ω
600
Fig . 7
Fig . 6
150nF
(120nF)
100nF*
TXA1
270
(220)
600
22
μ
F
22μF
560
120
TXA1
RXA
1k
1k
750
750
(820)
LINE
RXA
10nF
10nF
1nF
10k
1nF
10k
LINE
TXA2
TXA2
*Note: 100nF capacitor should have
a temperature stable dielectric
Insertion Loss (Line to RXA): 2.8dB @ 2kHz
Frequency Response : ±0.2dB 30Hz – 10kHz
Return Loss: 20dB 200Hz – 4kHz
Insertion Loss (Line to RXA): 2.2dB @ 2kHz
Frequency Response : ±0.5dB 50Hz – 4kHz
Return Loss: 20dB 200Hz – 4kHz
Transhybrid Loss: 30dB 50Hz – 10kHz
Transhybrid Loss: 18dB 200Hz – 4kHz
600Ω Instrumentation
CERTIFICATION
Certified under the IEC CB scheme (Certificate
DK-8570) to IEC 60950-1-2001, sub-clauses 1.5,
1.5.1, 1.5.2, 1.7.1, 2.9, 2.9.1, 2.9.2, 2.9.3, 2.10,
2.10.1, 2.10.2, 2.10.3, 2.10.3.1, 2.10.3.3, 2.10.4,
2.10.5, 2.10.5.1, 2.10.5.2, 2.10.5.4, 4.7, 4.7.1
(classV-1), 4.7.3, 4.7.3.1, 4.7.3.4, 5.2, 5.2.1, 5.2.2,
6.1.2.1 (Finland, Norway, Sweden national
deviations) for a maximum working voltage of
250Vrms, nominal mains supply voltage not
exceeding 300Vrms and a maximum operating
temperature of 70ºC in Pollution Degree 2
environments.
Ω
Fig . 8
600
47
μ
F*
47μF*
6.8nF
6.8nF
Ω
Ω
600
600
*
If no DC block required, one of these capacitors can be removed and
the other set to 22 F, or, if preferred, both capacitors can be eliminated.
μ
Certified to EN 60950-1:2001 (Demko Certificate
140243-01).
Insertion Loss: 1.5dB @ 2kHz
Frequency Response : ±0.2dB 20Hz – 20kHz
Return Loss: 16dB 20Hz – 20kHz
Recognized under the Component Recognition
Program of Underwriters Laboratories Inc. to US and
Canadian
requirements
CAN/CSA
C22.2
SAFETY
No. 60950-1-03/UL60950-1, First Edition, based on
IEC 60950-1, First Edition, maximum working
voltage 180Vrms (creepage), 420V peak
(clearance), Pollution Degree 2, supplementary
insulation.
Constructed in accordance with IEC 60950-1,
EN 60950-1, and UL 60950-1, supplementary
insulation, 250Vrms maximum working voltage,
flammability class V-0.
UL File number E203175.
There are no special installation requirements
(beyond attending to usual PCB track separations)
since the integral cover provides supplementary
insulation from its external faces to internal core
and windings.
Additionally, Profec Technologies certifies all
transformers as providing voltage isolation of
2.12kVrms, 3kV DC minimum. All shipments are
supported by a certificate of conformity to current
applicable safety standards.
Patented
ETALDOC 591/11
Page 4 of 6
December 2005