PGE 608 33
Optical/Control Characteristics
Optical / control characteristics over recommended operating conditions, unless otherwise noted.
Parameter
Symbol
Min
Typical
Max
Unit
Operating wavelength
Input power range
Output power
Noise figure
Polarization mode dispersion
Polarization dependent gain
Pump power to signal power ratio at output port
Optical return loss atinput/output
Transient suppression (Hight -3 dBm, Raise -20
ms)
l
P
I
P
O
NF
PMD
PDG
PSR
RL
T
Supp
1530
-10
13
6.0
1560
3
0.3
±0.2
-25
30
250
nm
dBm
dBm
dB
ps
dB
dB
dB
ms
Electrical Characteristics
Parameter
Symbol
Min
Typ
Max
Unit
Power supply voltage
Power supply current
Power supply ripple Noise (Peak to Peak)
Power dissipation - end of life
V
I
P
D
3.1
3.3
0.8
3
3.5
2
2
7
V
A
%
W
Recommended Operating Conditions
Parameter
Symbol
Min
Typ
Max
Unit
Operating case temperature
T
C
0
35
65
ºC
Absolute Maximum Ratings
Parameter
Symbol
Min
Typ
Max
Unit
Storage temperature
T
Stg
-40
20
75
ºC
CAUTION:
Stresses outside those listed in ”Absolute Maximum Ratings” may cause permanent damage to the device.
This is a stress only rating and operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied.
3