PBL 402 15
Operating conditions:
Parameter
Temperature range
Supply voltage range
Shutdown supply current
Supply current
Stand-by turn on time
(a)
Receive turn on time
(b)
Transmit turn on time
(b)
Condition
Fully compliant
Operational
Symbol
T
AMB
Vcc
I
OFF
I
ACTIVE
τ
ON
τ
RXON
τ
TXON
Min.
-20
-40
2.7
6
3
3
3
Typ.
Max.
70
85
4.5
2
Unit
°C
V
µA
mA
µs
µs
µs
One slot duplex communication
a. Time may depend upon settling time of the limiting strip DC correction feedback.
b. Time for the receive or transmit gain to be within 1 dB of its final value.
57mA
Typical current consumption
51mA
17mA
Tx
19mA
Rx
t
Transmit, 1 slot
Setup to transmit, (blind slot)
10 slots
Receive, 1 slot
Setup to receive, (blind slot)
Figure 7. Typical current consumtion.
Digital I/O Parameters
The digital output PA_GATE is served of the V
CC
RF/GndRF supply. All other digital signals are served of the V
CC
PLL/GndPLL
supply. The digital signals are EN, RXEN,TXEN, ST, D, CK, GATE, LD, MOD and SHOLD.
Parameter
Input voltage high
Input voltage low
Output voltage high
Output voltage low
Digital input capacitance
Digital input resistance
Digital load capacitance
Digital load resistance
Condition
Symbol
V
IH
V
IL
V
OH
V
OL
C
DI
R
DI
C
DL
R
DL
Min.
2.1
0.6
V
CC
-0.4
V
CC
-0.2
0.6
2
100
4
30
Typ.
Max.
Unit
V
V
V
V
pF
kΩ
pF
kΩ