PBL 386 50/2  
The current limit (reference C in figure  
13) is adjusted by connecting a resistor,  
RLC, between terminal PLC and ground  
according to the equation:  
receive output via the resistor RRX, is dc  
biased with +1.25V. This makes it  
possible to compensate for currents  
floating due to dc voltage differences  
between RSN and the CODEC output  
without using any capacitors. This is  
done by connecting a resistor RR be-  
tween the RSN terminal and ground.  
With current directions defined as in  
figure 14, current summation gives:  
Battery Feed  
The PBL 386 50/2 SLIC emulate  
resistive loop feed, programmable  
between 2·50and 2·900 , with  
adjustable current limitation. In the  
current limited region the loop current  
has a slight slope corresponding to  
2·30 k, see figure 13 reference B.  
The open loop voltage measured  
between the TIPX and RINGX terminals  
is tracking the battery voltage VBat. The  
signalling headroom, or overhead voltage  
1000  
LProg + 4  
RLC  
=
I
where RLC is in kfor ILProg in mA.  
A second, lower battery voltage may be  
connected to the device at terminal  
VBAT2 to reduce short loop power  
dissipation. The SLIC automatically  
switches between the two battery supply  
voltages without need for external  
control. The silent battery switching  
occurs when the line voltage passes the  
value |VB2| - 40·IL - (VOHVirt -1.3),  
if IL > 6 mA.  
For correct functionality it is important  
to connect the terminal VBAT2 to the  
second power supply via the diode DVB2  
in figure 12.  
An optional diode DBB connected  
between terminal VB and the VB2 power  
supply, see figure 12, will make sure that  
the SLIC continues to work on the  
second battery even if the first battery  
voltage disappears.  
IRSN = IRT + IRRX + IRR  
=
1,25 1,25 VCODEC  
1,25  
RR  
VTRO, is programmable with a resistor ROV  
+
+
RT  
RRX  
connected between terminal POV on the  
SLIC and ground. Please refer to section  
“Programmable overhead voltage(POV)”.  
The battery voltage overhead, VOH  
depends on the programmed signal  
overhead voltage VTRO. VOH defines the  
TIP to RING voltage at open loop  
conditions according to VTR(at IL = 0 mA)  
where VCODEC is the reference voltage of  
the CODEC at the receive output.  
From this equation the resistor RR can be  
calculated as  
,
1,25  
RR  
=
= |VBat| - VOH  
.
1,25 VCODEC  
1,25  
RT  
IRSN  
Refer to table 2 for typical values on  
VOH and VOHVirt. The overhead voltage is  
changed when the line current is ap-  
proaching open loop conditions. To  
ensure maximum open loop voltage,  
even with a leaking telephone line, this  
occurs at a line current of approximately  
6 mA. When the overhead voltage has  
changed, the line voltage is kept nearly  
constant with a steep slope correspond-  
ing to 2·25 (reference G in figure 13).  
The virtual battery overhead, VOHVirt, is  
defined as the difference between the  
battery voltage and the crossing point of  
all possible resistive feeding slopes, see  
figure 13 reference J. The virtual battery  
overhead is a theoretical constant  
RRX  
For values on IRSN, see table 3.  
The resistor RR has no influence on the  
ac transmission.  
If a second battery voltage is not used,  
VBAT2 is connected to VBAT on the  
SLIC and CVB2, DBB and DVB2 are removed.  
SLIC  
IRSN [µA]  
PBL 386 50/2  
-155  
Metering applications  
For designs with metering applications  
please contact Ericsson Microelectronics  
for assistance.  
Table 3. The SLIC internal bias current  
with the direction of the current defined  
as positive when floating into the terminal  
RSN.  
CODEC Receive Interface  
Programmable overhead voltage(POV)  
The PBL 386 50/2 SLIC have got a  
completely new receive interface at the  
four wire side which makes it possible to  
reduce the number of capacitors in the  
applications and to fit both single and  
dual battery feed CODECs. The RSN  
terminal, connecting to the CODEC  
needed to be able to calculate the  
feeding characteristics.  
With the POV function the overhead  
voltage can be increased.  
If the POV pin is left open the overhead  
voltage is internally set to 3.2 VPeak in off-  
SLIC  
VOH(typ)  
[V]  
VOHVirt(typ)  
[V]  
PBL 386 50/2 3.0 +VTRO 4.9 +VTRO  
12  
11  
10  
9
Table 2. Battery overhead.  
8
off-hook  
on-hook  
7
6
5
4
3
2
The resistive loop feed (reference D in  
figure 13) is programmed by connecting  
a resistor, RSG, between terminals PSG  
and VBAT according to the equation:  
1
0
RSG + 2·104  
RFeed  
=
+ 2RF  
0
10  
20  
30  
40  
50  
60  
200  
R
ov  
(K)  
where RFeed is in for RSG and RF in .  
Figure 11. Programmable overhead voltage (POV). RL = 600 or .  
12