Ericsson Internal
E
ETORHOL, EKAMAGN, EJANARV
PRODUCT SPEC
1 (9)
Prepared (also subject responsible if other)
No.
2/1301-BMR 451 0002 Uen
4
Technical Specification
Approved
Checked
Date
Rev
Reference
EN/LZT 146 401 R4A May 2015
BMR 451 Digital PoL Regulators
Input 4.5-14 V, Output up to 40 A / 132 W
SEC/D (Julia You)
ETORHOL
2010-03-02
E
© Ericsson AB
Absolute Maximum Ratings
Characteristics
min
-40
-40
-0.3
0.6
typ
max
120
125
16
Unit
°C
°C
V
TP1
TS
VI
Operating temperature (see Thermal Consideration section)
Storage temperature
Input voltage (See Operating Information Section for input and output voltage relations)
VO
PO
Output voltage
Output power
3.6
V
132
6.5
W
V
Logic I/O voltage
CTRL, SA(0,1), SALERT, SCL, SDA, FLEX
DGND, -S, GND
-0.3
-0.3
-0.3
Ground voltage differential
Analog pin voltage
0.3
V
VOUT, +S
6.5
V
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and
performance may degrade in an unspecified manner.
Fundamental Circuit Diagram
VIN
VOUT
GND
+S
-S
SCL
DPWM Controller and I/O
SDA
SALERT
CTRL
DGND
SA0
SA1
FLEX