 浏览型号BMR4511002/XXXC的Datasheet PDF文件第14页浏览型号BMR4511002/XXXC的Datasheet PDF文件第15页浏览型号BMR4511002/XXXC的Datasheet PDF文件第16页浏览型号BMR4511002/XXXC的Datasheet PDF文件第17页浏览型号BMR4511002/XXXC的Datasheet PDF文件第19页浏览型号BMR4511002/XXXC的Datasheet PDF文件第20页浏览型号BMR4511002/XXXC的Datasheet PDF文件第21页浏览型号BMR4511002/XXXC的Datasheet PDF文件第22页  
E
18  
Technical Specification  
EN/LZT 146 401 R4A May 2015  
BMR 451 Digital PoL Regulators  
Input 4.5-14 V, Output up to 40 A / 132 W  
© Ericsson AB  
PMBus Interface  
SA0/SA1 Index  
SA0/SA1 Index  
RSA0/RSA1 [k]  
RSA0/RSA1 [k]  
The regulator provides a digital PMBus interface that enables  
the user to monitor the input and output parameters. The  
PMBus interface can also be used for configuration of the  
regulator. The products can be used with any standard 2-wire  
I2C or SMBus host device. In addition, the device is compatible  
with PMBus version 1.1 and includes an SALERT line to help  
mitigate bandwidth limitations related to continuous fault  
monitoring. The PMBus signals, SCL, SDA, SALERT requires  
passive pull-up resistors as stated in the SMBus Specification.  
1
0
10  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
34.8  
38.3  
42.2  
46.4  
51.1  
56.2  
61.9  
68.1  
75  
2
1
11  
3
2
12.1  
13.3  
14.7  
16.2  
17.8  
19.6  
21.5  
23.7  
26.1  
28.7  
31.6  
4
3
5
4
6
5
7
6
8
7
Monitoring via PMBus  
9
8
A system controller can monitor a wide variety of different  
parameters through the PMBus interface. The controller can  
monitor for fault condition by monitoring the SALERT pin,  
which will be asserted when any number of pre-configured  
fault or warning conditions occur. The system controller can  
also continuously monitor for any number of power conversion  
parameters including but not limited to the following:  
10  
9
82.5  
90.9  
100  
11  
10  
12  
11  
13  
12  
14  
The PMBus address follows the equation below:  
15  
Input voltage  
Output voltage  
Output current  
Internal junction temperature  
Switching frequency  
Duty cycle  
16  
PMBus Address = 25 x (SA1 index) + (SA0 index)  
17  
The user can theoretically configure up to 625 unique PMBus  
18  
addresses, however the PMBus address range is inherently  
limited to 128. Therefore, the user should use index values 0 -  
4 on the SA1 pin and the full range of index values on the SA0  
pin, which will provide 124 device address combinations (The  
address 0d75 is allocated for production needs and can not be  
used.). The user shall also be aware of further limitations of the  
address space as stated in the SMBus Specification(Note that  
0-12, 40, 44, 45, 55, 64-68 in decimal are reserved and may  
not be usable).  
Software Tools for Design and Production  
Ericsson provides software for configuration and monitoring of  
this product via the PMBus interface.  
For more information please contact your local  
Ericsson sales representative.  
PMBus Addressing  
The PMBus address should be configured with resistors  
connected between SA0 and SA1 pin to the –S pin, as shown  
in the figure. Recommended resistor values for hard-wiring  
PMBus addresses (series E96, 1% tolerance resistors  
suggested) are shown in the table.  
SA0  
SA1  
R
R
SA1  
SA0  
S  
Schematic of connection of address resistors.  