S1D15E06 Series
Instruction Setup Example (Reference)
(1) Initial setup
V
DD - VSS power turns on when RES terminal = LOW.
Stable power supply
*1
Release the reset state. (RES terminal = HIGH)
Function setup by command entry (set by users)
(12) Column address set direction
(5) Common output status select
(3) Display normal/reverse
(4) Display all lighting ON/OFF
(18) Set the duty
(2) Display OFF mode select
(27) LCD voltage select
(28) Electronic volume
(31) Temperature gradient set
(When the n-line invert drive is not used)
Function setup by command entry (set by users)
(13) n-line invert drive register set
(14) n-line ON/OFF
(When the external oscillator circuit is used)
Enter the external clock
Function setup by command entry (set by users)
(24) Built-in oscillator circuit frequency select
(23) Built-in oscillator circuit ON/OFF
(When the external LCD power supply circuit is used)
External LCD power supply entry
Function setup by command entry (set by users)
(25) Power control set
1. Step-up circuit ON
2. V
C regulator circuit ON
3. LCDV circuit ON*2
Initialization completed
Note: *1 Display data RAM contents are not determined even in the initialized state after resetting. See “6.7 Reset
Circuit” in the “6. Function Description”.
*2 100ms or more should be kept from VC regulator circuit ON to LCDV circuit ON.
* Numerals in the command parenthesis correspond to the numerals of the items in Command Description.