S1D15E06 Series
Command code
Command
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
Function
(26) Step-up CK
Frequency Select
0
1
1
1
0
0
0
*
1
0
0
0
0
0
1
Frequency
(27) Liquid Crystal Drive
Voltage Select
0
1
1
1
0
0
0
*
0
*
1
*
0
*
1
*
0
*
1
1
VC range
(28) Electronic Volume
Mode Set
0
1
0
1
0
0
0
0
0
0
1
Electronic Volume
1
1
0
*
Electronic volume
VC output voltage is set to the
Register Set
electronic volume register. 128 states
(29) Discharge ON/OFF
0
0
0
1
1
1
1
1
0
0
0
0
1
1
1
0
1
0
1
0
1
Discharges Power supply circuit
connection capacitor.
0: OFF (normal), 1: ON
Power Save 0: OFF, 1: ON
Sets to 8 steps.
(30) Power Save ON/OFF
(31) Temperature
Gradient Select
1
0
*
0
1
*
1
0
*
0
0
*
1
1
*
0
1
0
1
0
0
Temperature gradient
(32) Stator Read
0
1
1
0
0
1
1
*
0
*
0
*
0
*
1
1
1
0
Issues the temperature gradient
*Temperature gradient select bit.
(33) Reset
0
1
0
1
1
1
0
0
0
1
0
Resets the column, page and
address registers.Resets the read
modify write function.
(34) MLS drive selection
(35) NOP
0
1
1
1
0
0
1
*
0
*
0
*
1
*
1
1
0
0
MLS drive method
MLS drive method 0 : Dispersive, 1 : Nondispersive
0
1
0
1
1
1
0
0
0
1
1
Non-operation command
46
EPSON
Rev. 2.1