Epson Research and Development
Page 9
Vancouver Design Center
Installation for CEPC Environment
Windows CE v2.0 can be loaded on a PC using a floppy drive or a hard drive. The two methods
are described below:
1. To load CEPC from a floppy drive:
a. Create a DOS bootable floppy disk.
b. Edit CONFIG.SYS on the floppy disk to contain the following line only.
device=a:\himem.sys
c. Edit AUTOEXEC.BAT on the floppy disk to contain the following lines.
mode com1:9600,n,8,1
loadcepc /B:9600 /C:1 c:\wince\release\nk.bin
d. Copy LOADCEPC.EXE from c:\wince\public\common\oak\bin to the bootable
floppy disk.
e. Confirm that NK.BIN is located in c:\wince\release.
f. Reboot the system from the bootable floppy disk.
2. To load CEPC from a hard drive:
a. Copy LOADCEPC.EXE to the root directory of the hard drive.
b. Edit CONFIG.SYS on the hard drive to contain the following line only.
device=c:\himem.sys
c. Edit AUTOEXEC.BAT on the hard drive to contain the following lines.
mode com1:9600,n,8,1
loadcepc /B:9600 /C:1 c:\wince\release\nk.bin
d. Confirm that NK.BIN is located in c:\wince\release.
e. Reboot the system from the hard drive.
Windows® CE Display Drivers
Issue Date: 01/02/06
S1D13506