Page 6
Epson Research and Development
Vancouver Design Center
FW addr addr data...
Fills a specified address range with 16-bit data (words).
Where:
addr
data
Address range to be filled (hex).
Data to be written (hex). Data can be a list of words that will
be repeated for the duration of the fill. To use decimal
values, attach a “t” suffix to the value. (e.g. 100t is 100
decimal).
H [lines]
Sets the number of lines of data that will be displayed at a time. The display will be halted
after the specified number of lines. Setting the number of lines to 0 will disable the halt
function and allow the data to continue displaying until all data has been shown.
Where:
lines
Number of lines that will be shown before halting the
displayed data (decimal value).
I [?] {LCD|CRT|TV} [d=iCrtTv] [COMP | SVIDEO] [FLICKER=ON | OFF]
Initializes the S1D13506 registers for a given display type.
Where:
?
Displays a help message.
LCD
CRT
TV
Initializes the LCD registers.
Initializes the CRT registers.
Initializes the TV registers.
d = iCrtTv
Initializes the CRT/TV for a display configuration based on
the following table.
Table 1: iCrtTv Selection
iCrtTv
Resolution
640x480
800x600
752x484
696x436
640x480
920x572
856x518
800x572
640x480
Display Type
CRT
0
1
2
3
4
5
6
7
8
CRT
TV (NTSC)
TV (NTSC)
TV (NTSC)
TV (PAL)
TV (PAL)
TV (PAL)
TV (PAL)
COMP
SVIDEO
Initializes for Composite video output (TV only).
Initializes for SVideo output (TV only).
FLICKER=ON
FLICKER=OFF
Initializes for Flicker Filter enabled (TV only).
Initializes for Flicker Filter disabled (TV only).
S1D13506
X25B-B-003-02
13506PLAY Diagnostic Utility
Issue Date: 01/02/06