Pressure sensors
C32 series
Absolute pressure sensor die for wet media
Preliminary data
Operating pressures and ordering codes
Parameter @ 25 °C, VDD = 5 V
Symbol
Typ.
Typ.
Typ.
Typ.
Units
Operating pressure 4)
pr
1.6
4
10
25
bar
Offset voltage 10)
[min/typ/max]
V0
–50/–15/25
–40/–5/25
–35/–3/25
–30/0/25
mV
–
Temperature coefficient
of offset voltage (unglued) 11)
[typ]
TCV0
–20
–10
–7
–6
µV/VK
µV/VK
% FS
+
TCV0
–10
5
3
3
Nonlinearity 14) [typ/max]
L
0.2/ 0.3
0.2/ 0.3
0.2/ 0.3
0.2/ 0.3
Sensitivity 13)
[min/typ/max]
S
45/70/95
23/30/38
9/12/15
3.6/4.8/6
mV/bar
Product type
Ordering code
Other operating pressures upon request.