Data and signal line chokes
ACT45B
Common-mode chokes, EIA 1812
Technical data and measuring conditions
Rated voltage VR
50 V DC
Max. component temperature
Rated current IR
+150 °C
Referred to 50 Hz and +20 °C
Rated inductance LR
Measured with Agilent 4284A at 100 kHz, 100 mV, +20 °C
Inductance is specified in common-mode
Inductance tolerance
–30/+50% at +20 °C
Stray inductance Lstray,typ
Measured with Agilent 4284A at 100 kHz, 100 mV, +20 °C,
typical values
DC resistance Rmax
Insulation resistance (min)
Rated impedance Zmin
Rated impedance Ztyp
Solderability
Measured at +20 qC, specified per winding
10 M:,ꢀmeasured at 50 V DC
Measured at +20 °C, 10 MHz, 100 mV in common-mode
Measured at +20 °C, 10 MHz, 100 mV in common-mode
Dip and look method Sn95.5Ag3.8Cu0.7:
+(245 r5) °C, (3 r0.3) s
Wetting of soldering area tꢀ90%
(based on IEC 60068-2-58)
Resistance to soldering heat
Climatic category
+260 °C, 40 s as referenced in JEDEC J-STD 020D
40/150/56 (to IEC 60068-1)
Storage conditions (packaged)
Weight
–25 °C … +40 °C, dꢀ75% RH
Approx. 0.14 g
Characteristics and ordering codes
LR
Lstray,typ IR
Rmax Zmin
Ztyp
Internal code
Ordering code
μH
μH
mA
:
:
:
51
100
0.15
0.20
200
150
1.0
3.0
1000 2000 B82787C0513H002 ACT45B-510-2P-TL003
2000 5000 B82787C0104H002 ACT45B-101-2P-TL003
Please read Cautions and warnings and
Important notes at the end of this document.
4
08/12