Embedded Power for
Business-Critical Continuity
Rev.03.07.07
bxa10
Specifications Contd.
3 of 4
INPUT
OUTPUT
VOLTAGE
5 V
OUTPUT
CURRENT
2 A
INPUT
CURRENT
1.1 A
TYPICAL
EFFICIENCY
81%
REGULATION (Typ.)
MODEL
OVP
(1)
(3,9,10)
VOLTAGE
9-18 Vdc
9-18 Vdc
9-18 Vdc
18-75 Vdc
18-75 Vdc
18-75 Vdc
18-75 Vdc
LINE
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
LOAD
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
NUMBER
6.2 Vdc
18 Vdc
12 Vdc
6.8 Vdc
12 Vdc
30 Vdc
36 Vdc
BXA10-12S05J
BXA10-12S15J
BXA10-12D05J
BXA10-48S05J
BXA10-48D05J
BXA10-48D12J
BXA10-48D15J
15 V
0.67 A
1 A
1.05 A
1.05 A
0.26 A
0.26 A
0.25 A
0.25 A
85%
5 V
81%
5 V
2 A
82%
5 V
1 A
82%
12 V
0.416 A
0.333 A
84%
15 V
84%
Notes
Please check with your local representative or the Model Search Tool for the
latest available product codes.
1
2
At nominal input and output voltage and maximum load.
Output ripple can be reduced to <50 mV with the addition of a 33 μF, 25 V,
AVX-TPS (or equivalent) tantalum capacitor. Consult factory for further
information.
3
For units with optional remote ON/OFF, please add the suffix ‘-S’ to the model
number: e.g. BXA10-48S05-SJ. Maximum open pin voltage 14 Vdc.
Assumes balanced loads on dual output models.
High impedance source/long input power cable may necessitate the
introduction of an input filter.
Typical 9 Vdc to 18 Vdc model start-up voltage is 9 V. Maximum start-up
voltage is 9.5 V (>0 °C) or 9.7 V (<0 °C).
It is recommended that an IEC127, 250 V, fast blow fuse is used rated at 4 A
for nominal 12 V models and 2 A for 48 V models.
PIN CONNECTIONS
4
5
PIN NUMBER
SINGLE OUTPUT
+Vin
DUAL OUTPUT
+ Vin
1
2
6
7
8
– Vin
– Vin
3
+ Vout
+ Vout
To achieve compliance to EN55022-A and FCC part 15 Class A, external
capacitors of the following values are needed:
4
No Pin
Common
– Vout
Model
BXA10-12xxxx
BXA10-48xxxx
C1*
C2
C3
5
– Vout
10 μF film, 25 V
10 μF film, 100 V
0.22 μF film
0.22 μF film
0.22 μF film
0.22 μF film
6*
Remote ON/OFF
Remote ON/OFF
(C2, C3 voltage rating application dependent)
* Siemens P.N. B32512-J1106-J or equivalent.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
* Optional remote ON/OFF pin. Add Suffix ‘-S’ to the model number (Note 3).
9
+ Input
10 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
C1
BXA10
Input Return
C2
C3
Ground Plane