Embedded Power for
Business-Critical Continuity
Rev.03.07.07
bxa10
Specifications
2 of 4
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
OUTPUT SPECIFICATIONS
Line regulation
EMC CHARACTERISTICS
LL to HL, single output
LL to HL, dual output
0.2%
0.2%
Conducted emissions
ESD air
EN55022, FCC (See Note 8)
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
EN61000-4-2, level 2
EN61000-4-2, level 3
EN61000-4-5, level 2
EN61000-4-4, level 2
EN61000-4-3, level 3
EN61000-4-6, level 3
ESD contact
Surge
Load regulation
Minimum load
10% to 100% FL (See Note 4)
48 V models
0.5%
Fast transients
Radiated immunity
Conducted immunity
10% full load
No minimum load
12 V models
Overshoot
At start-up
10% max.
GENERAL SPECIFICATIONS
Efficiency
Ripple and noise
(See Note 2)
5 Hz to 20 MHz
100 mV pk-pk, max.
20 mV rms
See table
Isolation voltage
Input/output
Input or output to case
1500 Vdc
1000 Vdc
Transient response
25% load step
2.0% max. dev.,
250 μs recovery
to within 1.0%
Switching frequency
Fixed
400 kHz
Approvals and
standards
Safety
VDE0805, EN60950, IEC950
UL1950, CSA C22.2 No. 950
Temperature coefficient
Overvoltage protection
Short circuit protection
0.02%/°C max.
See table
Clamp type
Hiccup
Case material
Material flammability
Weight
Black coated, six-sided metal case
UL94V-0
Continuous
automatic recovery
20 g (0.71 oz)
INPUT SPECIFICATIONS
Input voltage range
MTBF
MIL-HDBK-217F
Bellcore
519,000 hours
>2 million hours
12 Vdc (See Note 6)
48 Vdc
9-18 Vdc
18-75 Vdc
ENVIRONMENTAL SPECIFICATIONS
Input filter
Pi type
Thermal performance
Operating ambient
-25 °C to +71 °C
Start up surge current
Resistive load
1.5 A max.
(See derating curve)
Non-operating amb.
Case
Remote ON/OFF
ON (See Note 3)
OFF
Open collector compatible
High impedance >400 kΩ
Low impedance <1.0 kΩ
<1.5 mA
-55 °C to +125 °C
+110 °C max.
See derating curve
Derating
Cooling
Free air convection cooled
OFF idle current
Relative humidity
Altitude
Non-condensing
5% to 95% RH
Start-up time
1.6 s, max.
Operating
Non operating
10,000 feet max.
40,000 feet max.
Vibration
5-500 MHz
2.5 G rms (approx.)