EM77950
BB Controller
Bit 7 (ADRUN): ADC starts to RUN
0 : reset on completion of the conversion; this bit cannot be reset by
software.
1 : A/D conversion is started; this bit can be set by software.
Bits 4 and 5 are reserved.
7.3.14 PWM Control Register – PWMCR (0x98)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
-
-
-
-
S_PWM1 S_PWM0
-
-
Bit 2 (S_PWM0): Selected PWM0 output enable.
Bit 3 (S_PWM1): Selected PWM1 output enable.
0: disable PWM output
1: enable enable PWM output
Bits 0, 1 and 4 ~ 7 are reserved.
7.3.15 BB Interrupt Control Register – RFINTE (0x99)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
TX_
EMPTYE
LINK_
DISE
LOCK_OU LOCK_
TE INE
CSDE
TX_AEE RX_AFE
RX_OFE
Bit 0 (LOCK_INE):
LOCK IN interrupt enable bit.
Bit 1 (LOCK_OUTE): LOCK OUT interrupt enable bit.
Bit 2 (LINK_DISE):
Bit 3 (RX_OFE):
LINK_DIS interrupt enable bit.
RX FIFO full interrupt enable bit.
Bit 4 (TX_EMPTYE): TX EMPTY interrupt enable bit.
Bit 5 (RX_AFE):
Bit 6 (TX_AEE):
Bit 7 (CSDE):
RX FIFO almost full interrupt enable bit.
TX FIFO almost empty interrupt enable bit.
carrier-sense interrupt enable bit.
0: disable interrupt function
1: enable interrupt function
Product Specification (V1.0) 10.09.2007
(This specification is subject to change without further notice)
• 37