EM65570
68COM/ 98SEG 65K Color STN LCD Driver
7.26.2 Display Data
End of initialization
Setting Operational Functions
* Setting display start common
* Setting address increment control
* Setting X address
* Setting Y address
Setting Operational Functions
* Write dsiplay data
Setting Operational Functions
* Setting display on/off control
(ON/OFF= "1")
End of display data setting
Figure 7-24b Display Data Register Setting Sequential Flow
7.26.3 Power OFF
Any condition
Setting Operational Functions
* Setting HALT=1 or make reset operation
(LCD driver output VSS level)
* Setting DIS= "1"
(Discharge V0-V4 capacitor)
WAIT
Power OFF ( VEE,VDD)
Figure 7-24c Power Off Register Setting Sequential Flow
54 •
Product Specification (V1.0) 09.05.2005
(This specification is subject to change without further notice)