EBE41EF8ABFA
CKE (input pin)
CKE controls power down and self-refresh. The power down and the self-refresh commands are entered when the
CKE is driven low and exited when it resumes to high.
The CKE level must be kept for 1 CK cycle at least, that is, if CKE changes at the cross point of the CK rising edge
and the VREF level with proper setup time tIS, at the next CK rising edge CKE level must be kept with proper hold
time tIH.
DQ and CB (input and output pins)
Data are input to and output from these pins.
DQS and /DQS (input and output pin)
DQS and /DQS provide the read data strobes (as output) and the write data strobes (as input).
DM (input pins)
DM is the reference signal of the data input mask function. DMs are sampled at the cross point of DQS and /DQS.
VDD (power supply pins)
1.8V is applied. (VDD is for the internal circuit.)
VDDSPD (power supply pin)
1.8V is applied (For serial EEPROM).
VSS (power supply pin)
Ground is connected.
Detailed Operation Part and Timing Waveforms
Refer to the EDE2104ABSE, EDE2108ABSE datasheet (E1196E).
Preliminary Data Sheet E1285E10 (Ver. 1.0)
27