EBE10RD4ABFA
DC Characteristics 1 (TC = 0 to +85°C, VDD = 1.8V ± 0.1V, VSS = 0V)
Parameter
Symbol Grade
max
Unit
Test condition
one bank; tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
-5C
2440
Operating current
(ACT-PRE)
IDD0
mA
-4A, -4C
2120
2760
one bank; IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
-5C
tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD); tRCD = tRCD (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
Operating current
(ACT-READ-PRE)
IDD1
mA
-4A, -4C
2430
all banks idle;
tCK = tCK (IDD);
CKE is L;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
-5C
700
620
970
840
Precharge power-down
standby current
IDD2P
IDD2Q
mA
mA
-4A, -4C
-5C
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
Precharge quiet standby
current
-4A, -4C
all banks idle;
-5C
1060
930
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are
SWITCHING;
Idle standby current
IDD2N
mA
-4A, -4C
Data bus inputs are SWITCHING
all banks open;
tCK = tCK (IDD);
CKE is L;
Other control and
address bus inputs are
STABLE;
Data bus inputs are
FLOATING
-5C
1240
1110
Fast PDN Exit
MRS(12) = 0
IDD3P-F
IDD3P-S
mA
mA
-4A, -4C
Active power-down
standby current
-5C
970
840
Slow PDN Exit
MRS(12) = 1
-4A, -4C
all banks open;
tCK = tCK (IDD), tRAS = tRAS max.(IDD),
tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Other control and address bus inputs are
SWITCHING;
-5C
1720
1580
3660
3060
3660
3060
Active standby current
IDD3N
IDD4R
IDD4W
mA
mA
mA
-4A, -4C
-5C
Data bus inputs are SWITCHING
all banks open, continuous burst reads, IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP
(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
Operating current
(Burst read operating)
-4A, -4C
-5C
all banks open, continuous burst writes;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRAS = tRAS max.(IDD),
tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
Operating current
(Burst write operating)
-4A, -4C
Preliminary Data Sheet E0366E50 (Ver. 5.0)
11