欢迎访问ic37.com |
会员登录 免费注册
发布采购

GD25Q32C 参数 Datasheet PDF下载

GD25Q32C图片预览
型号: GD25Q32C
PDF下载: 下载PDF文件 查看货源
内容描述: [32M-bit Serial Flash]
分类和应用:
文件页数/大小: 50 页 / 3543 K
品牌: ELM [ ELM ELECTRONICS ]
 浏览型号GD25Q32C的Datasheet PDF文件第18页浏览型号GD25Q32C的Datasheet PDF文件第19页浏览型号GD25Q32C的Datasheet PDF文件第20页浏览型号GD25Q32C的Datasheet PDF文件第21页浏览型号GD25Q32C的Datasheet PDF文件第23页浏览型号GD25Q32C的Datasheet PDF文件第24页浏览型号GD25Q32C的Datasheet PDF文件第25页浏览型号GD25Q32C的Datasheet PDF文件第26页  
GD25Q32CxIGx 3.3V Uniform Sector Dual and Quad Serial Flash  
http://www.elm-tech.com  
The Burst with Wrap feature allows applications that use cache to quickly fetch a critical address and then fill  
the cache afterwards within a fixed length (8/16/32/64-byte) of data without issuing multiple read commands.  
The “Set Burst with Wrap” command allows three “Wrap Bits” W6-W4 to be set. The W4 bit is used to enable  
or disable the “Wrap Around” operation while W6-W5 is used to specify the length of the wrap around section  
within a page.  
7.12. Quad I/O Word Fast Read (E7H)  
The Quad I/O Word Fast Read command is similar to the Quad I/O Fast Read command except that the lowest  
address bit (A0) must equal 0 and only 2-dummy clock. The command sequence is shown in followed Figure15.  
The first byte addressed can be at any location. The address is automatically incremented to the next higher  
address after each byte of data is shifted out. The Quad Enable bit (QE) of Status Register (S9) must be set to  
enable for the Quad I/O Word Fast read command.  
Quad I/O Word Fast Read with “Continuous Read Mode”  
The Quad I/O Word Fast Read command can further reduce command overhead through setting the “Continuous  
Read Mode” bits (M7-0) after the input 3-byte address (A23-A0). If the “Continuous Read Mode” bits (M5-4)  
=(1, 0), then the next Quad I/O Word Fast Read command (after CS# is raised and then lowered) does not  
require the E7H command code. The command sequence is shown in followed Figure16. If the “Continuous  
Read Mode” bits (M5-4) do not equal to (1, 0), the next command requires the first E7H command code, thus  
returning to normal operation. A “Continuous Read Mode” Reset command can be used to reset (M5-4) before  
issuing normal command.  
Figure 15. Quad I/O Word Fast Read Sequence Diagram (M5-4 ≠ (1, 0))  
CS#  
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23  
SCLK  
Command  
E7H  
SI(IO0)  
4
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
SO(IO1)  
5
6
7
WP#(IO2)  
HOLD#(IO3)  
Dummy  
A23-16 A15-8 A7-0 M7-0  
Byte1 Byte2 Byte3  
Rev.1.0  
50 - 22  
 复制成功!