AT Command Descriptions (continued)  
formats the J1939 ID (ie Header) bits in such a way as  
to isolate the priority bits and group all the PGN  
information, while keeping the source address byte  
separate. If you prefer to see the ID information as four  
separate bytes (which a lot of the J1939 software  
seems to do), then simply turn off the formatting with  
JHF0. The CAF0 command has the same effect (and  
overrides the JHF setting), but also affects other  
formatting. The default setting is JHF1.  
LP  
[ go to the Low Power mode ]  
This command causes the ELM329 to shut off all  
but ‘essential services’ in order to reduce the power  
consumption to a minimum. The ELM329 will respond  
with an ‘OK’ (but no carriage return) and then, one  
second later, will change the state of the PwrCtrl  
outputs (pins 14 & 16) and will enter the low power  
(standby) mode. The IC can be brought back to normal  
operation with an RS232 input, CAN activity, or a  
rising edge at the IgnMon (pin 15) input, in addition to  
the usual methods of resetting the IC (power off then  
on, a low on pin 1, or a brownout). See the ‘Low Power  
Mode’ section (page 57) for more information.  
JS  
[ enables the J1939 SAE data format ]  
The AT JS command disables the automatic byte  
reordering that the JE command performs for you. If  
you wish to send data bytes to the J1939 vehicle  
without any manipulation of the byte order, then select  
JS formatting.  
Using the above example for engine temperature  
(PGN 00FEEE) with the data format set to JS, you  
must send the bytes to the ELM329 as EE FE 00 (this  
is also known as little-endian byte ordering).  
The JS type of data formatting is off by default.  
M0 and M1  
[ Memory off or on ]  
The ELM329 has internal ‘non-volatile’ memory  
that is capable of remembering the last protocol used,  
even after the power is turned off. This can be  
convenient if the IC is often used for one particular  
protocol, as that will be the first one attempted when  
next powered on. To enable this memory function, it is  
necessary to either use an AT command to select the  
M1 option, or to have chosen ‘memory on’ as the  
default power on mode (by connecting pin 5 of the  
ELM329 to a high logic level).  
JTM1  
[ J1939 Timer Multiplier to 1 ]  
This command sets the J1939 AT ST time  
multiplier to 1, reversing any changes made by JTM5.  
JTM1 is the default setting. It has no effect for non-  
J1939 protocols.  
When the memory function is enabled, each time  
that the ELM329 finds a valid OBD protocol, that  
protocol will be memorized (stored) and will become  
the new default. If the memory function is not enabled,  
JTM5  
[ J1939 Timer Multiplier to 5 ]  
protocols found during  
a
session will not be  
When using a J1939 protocol, it is occasionally  
useful to be able to set the AT ST time to values  
longer than one second. The JTM5 command will  
multiply the AT ST setting by a factor of 5, in order to  
provide longer times for the J1939 protocols (only). By  
default, this multiplier is off.  
memorized, and the ELM329 will always start at power  
up using the same (last saved) protocol.  
If the ELM329 is to be used in an environment  
where the protocol is constantly changing, it would  
likely be best to turn the memory function off, and  
issue an AT SP 0 command once. The SP 0 command  
tells the ELM329 to start in an 'Automatic' protocol  
search mode, which is the most useful for an unknown  
environment. ICs come from the factory set to this  
mode. If, however, you have only one vehicle that you  
regularly connect to, storing that vehicle’s protocol as  
the default would make the most sense.  
The default setting for the memory function is  
determined by the voltage level at pin 5 during power  
up (or system reset). If it is connected to a high level  
(VDD), then the memory function will be on by default.  
If pin 5 is connected to a low level, the memory saving  
will be off by default.  
L0 and L1  
[ Linefeeds off or on ]  
This option controls the sending of linefeed  
characters after each carriage return character. For  
AT L1, linefeeds will be generated after every carriage  
return character, and for AT L0, they will be off. Users  
will generally wish to have this option on if using a  
terminal program, but off if using a custom computer  
interface (as the extra characters transmitted will only  
serve to slow the communications down). The default  
setting is determined by the voltage at pin 7 during  
power on (or reset). If the level is high, then linefeeds  
are on by default; otherwise they will be off.  