欢迎访问ic37.com |
会员登录 免费注册
发布采购

ELM329P 参数 Datasheet PDF下载

ELM329P图片预览
型号: ELM329P
PDF下载: 下载PDF文件 查看货源
内容描述: CAN解释 [CAN Interpreter]
分类和应用:
文件页数/大小: 76 页 / 353 K
品牌: ELM [ ELM ELECTRONICS ]
 浏览型号ELM329P的Datasheet PDF文件第12页浏览型号ELM329P的Datasheet PDF文件第13页浏览型号ELM329P的Datasheet PDF文件第14页浏览型号ELM329P的Datasheet PDF文件第15页浏览型号ELM329P的Datasheet PDF文件第17页浏览型号ELM329P的Datasheet PDF文件第18页浏览型号ELM329P的Datasheet PDF文件第19页浏览型号ELM329P的Datasheet PDF文件第20页  
ELM329  
AT Command Descriptions (continued)  
FC SH wwxxyyzz  
[ Flow Control Set Header to… ]  
feature is most useful if you wish to perform the power  
control functions using your own software. If you  
disable the automatic response to a low input on this  
pin (by setting bit 2 of PP 0E to 0), then pin 15 will  
function as the RTS input. A low level on the input will  
not turn the power off, but it will interrupt any OBD  
activity that is in progress. All you need to do is detect  
the ‘STOPPED’ message that is sent when the  
ELM329 is interrupted, and then check the level at pin  
15 using AT IGN. If it is found to be OFF, you can  
perform an orderly shutdown yourself.  
This command is used to set the header (or ‘CAN  
ID’) bits for Flow Control responses with 29 bit CAN ID  
systems. Since the 8 nibbles define 32 bits, only the  
right-most 29 bits of those provided will be used - the  
most significant three bits are always ignored. This  
command only affects Flow Control mode 1.  
FC SM h  
[ Flow Control Set Mode to h ]  
This command sets how the ELM329 responds to  
First Frame messages when automatic Flow Control  
responses are enabled. The single digit provided can  
either be ‘0’ (the default) for fully automatic responses,  
‘1’ for completely user defined responses, or ‘2’ for  
user defined data bytes in the response. Note that FC  
modes 1 and 2 can only be enabled if you have  
defined the needed data and possibly ID bytes. If you  
have not, you will get an error message. More  
complete details and examples can be found in the  
Altering Flow Control Messages section (page 54).  
IN1  
[ read the level at INput 1 ]  
This command causes the ELM329 to read the  
logic level at pin 12. If it is at a low level, ‘0’ will be  
reported, while a high level results in a ‘1’. The level  
shown is subject to the hysteresis effects of the  
Schmitt trigger wave shaping of the input circuitry.  
IN2  
[ read the level at INput 2 ]  
This command causes the ELM329 to read the  
H0 and H1  
[ Headers off or on ]  
logic level at pin 13. If it is at a low level, ‘0’ will be  
reported, while a high level results in a ‘1’. The level  
shown is subject to the hysteresis effects of the  
Schmitt trigger wave shaping of the input circuitry.  
These commands control whether or not the  
header (ID and possibly DLC) bytes of information are  
shown in the responses from the vehicle. These are  
not normally shown by the ELM329, but may be of  
interest (especially if you receive multiple responses  
and wish to determine what modules they were from).  
Turning the headers on (with AT H1) actually  
shows more than just the header bytes – you will see  
the complete message as transmitted, including the  
PCI bytes, and the CAN data length code (DLC) if it  
has been enabled. The current version of this IC does  
not display the CAN CRC code.  
JE  
[ enables the J1939 ELM data format ]  
The J1939 standard requires that PGN requests  
be sent with the byte order reversed from the standard  
‘left-to-right’ order, which many of us would expect. For  
example, to send a request for the engine temperature  
(PGN 00FEEE), the data bytes are actually sent in the  
reverse order (ie EE FE 00), and the ELM329 would  
normally expect you to provide the data in that order  
for passing on to the vehicle.  
I
[ Identify yourself ]  
When experimenting, this constant need for byte  
reversals can be quite confusing, so we have defined  
an ELM format that reverses the bytes for you. When  
the J1939 ELM (JE) format is enabled, and you have a  
J1939 protocol selected, and you provide three data  
bytes to the ELM329, it will reverse the order for you  
before sending them to the ECU. To request the  
engine temperature PGN, you would send 00 FE EE  
(and not EE FE 00). The ‘JE’ type of automatic  
formatting is enabled by default.  
Issuing this command causes the chip to identify  
itself, by printing the startup product ID string (currently  
‘ELM329 v2.0’). Software can use this to determine  
exactly which integrated circuit it is talking to, without  
having to reset the IC.  
IGN  
[ read the IgnMon input level ]  
This command reads the signal level at pin 15. It  
assumes that the logic level is related to the ignition  
voltage, so if the input is at a high level, the response  
will be ‘ON’, and a low level will report ‘OFF’. This  
JHF0 and JHF1 [ J1939 Header Formatting off or on ]  
When printing responses, the ELM329 normally  
ELM329DSB  
Elm Electronics – Circuits for the Hobbyist  
www.elmelectronics.com  
16 of 76  
 复制成功!