ELM327  
AT Command Descriptions (continued)  
an 83.3 kbps baud rate, close the protocol, and then  
send the new values:  
the IC to perform a normal startup. Note that a reset of  
the PPs occurs quite quickly – if you are holding the  
jumper on for more than a few seconds and do not see  
the RS232 receive light flashing, remove the jumper  
and try again, as there may be a problem with your  
connection. This feature is only available beginning  
with v1.2, and is not a provided with any earlier  
versions of the ELM327 IC.  
>AT PC  
OK  
>AT PB C0 06  
OK  
>AT MA  
PP hh ON  
[ turn Programmable Parameter hh ON ]  
Values passed in this way do not affect those that  
are stored in the 2C and 2D Programmable  
Parameters, and are lost if the ELM327 is reset. If you  
want to make your settings persist over power cycles,  
then you should store them in the Programmable  
Parameter memory (don’t forget that there are two –  
USER1 and USER2.  
This command enables Programmable Parameter  
number hh. Once enabled, any value assigned using  
the PP hh SV command will be used where the factory  
default value was before. (All of the programmable  
parameter values are set to their default values at the  
factory, so enabling a programmable parameter before  
assigning a value to it will not cause problems.) The  
actual time when the value for this parameter becomes  
effective is determined by its type. Refer to the  
Programmable Parameters section (page 58) for more  
information on the types.  
PC  
[ Protocol Close ]  
There may be occasions where it is desirable to  
stop (deactivate) a protocol. Perhaps you are not using  
the automatic protocol finding, and wish to manually  
activate and deactivate protocols. Perhaps you wish to  
stop the sending of idle (wakeup) messages, or have  
another reason. The PC command is used in these  
cases to force a protocol to close.  
Note that ‘PP FF ON’ is a special command that  
enables all of the Programmable Parameters at the  
same time.  
PP hh SV yy [ Prog. Param. hh: Set the Value to yy ]  
A value is assigned to a Programmable Parameter  
using this command. The system will not be able to  
use this new value until the Programmable Parameter  
has been enabled, with PP hh ON.  
PP hh OFF  
[ turn Prog. Parameter hh OFF ]  
This command disables Programmable Parameter  
number hh. Any value assigned using the PP hh SV  
command will no longer be used, and the factory  
default setting will once again be in effect. The actual  
time when the new value for this parameter becomes  
effective is determined by its type. Refer to the  
Programmable Parameters section (page 58) for more  
information on the types.  
PPS  
[ Programmable Parameter Summary ]  
The complete range of current Programmable  
Parameters are displayed with this command (even  
those not yet implemented). Each is shown as a PP  
number followed by a colon and the value that is  
assigned to it. This is followed by a single digit – either  
‘N’ or ‘F’ to show that it is ON (enabled), or OFF  
(disabled), respectively. See the Programmable  
Parameters section for a more complete discussion.  
Note that ‘PP FF OFF’ is a special command that  
disables all of the Programmable Parameters, as if you  
had entered PP OFF for every possible one.  
It is possible to alter some of the Programmable  
Parameters so that it may be difficult, or even  
impossible, to communicate with the ELM327. If this  
occurs, there is a hardware means of resetting all of  
the Programmable Parameters at once. Connect a  
jumper from circuit common to pin 28, holding it there  
while powering up the ELM327 circuit. Hold it in  
position until you see the RS232 Receive LED begin to  
flash (which indicates that all of the PPs have been  
turned off). At this point, remove the jumper to allow  
R0 and R1  
[ Responses off or on ]  
These commands control the ELM327’s automatic  
receive (and display) of the messages returned by the  
vehicle. If responses have been turned off, the IC will  
not wait for a reply from the vehicle after sending a  
request, and will return immediately to wait for the next  
ELM327DSI  
Elm Electronics – Circuits for the Hobbyist  
www.elmelectronics.com  
22 of 82  
 复制成功!