7.24. Read Manufacture ID/Device ID Quad I/O (94H)
The Read Manufacturer/Device ID Quad I/O command is an alternative to the Release from Power-Down/
Device ID command that provides both the JEDEC assigned Manufacturer ID and the specific Device ID by
quad I/O.
The command is initiated by driving the CS# pin low and shifting the command code “94H” followed by a
24-bit address (A23-A0) of 000000H. After which, the Manufacturer ID and the Device ID are shifted out on
the falling edge of SCLK with most significant bit (MSB) first as shown in Figure26. If the 24-bit address is
initially set to 000001H, the Device ID will be read first.
Figure 26. Read Manufacture ID/Device ID Quad I/O Sequence Diagram
CS#
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
SCLK
Command
94H
SI(IO0)
4
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
SO(IO1)
5
6
7
WP#(IO2)
HOLD#(IO3)
MFR ID DID
A23-16 A15-8 A7-0 M7-0
Dummy
CS#
24 25 26 27 28 29 30 31
SCLK
SI(IO0)
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
SO(IO1)
WP#(IO2)
HOLD#(IO3)
MFR ID DID
MFR ID DID
(Repeat()Repeat)
(Repeat()Repeat)
Rev.1.0