 浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第4页浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第5页浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第6页浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第7页浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第9页浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第10页浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第11页浏览型号DNL04S0A0R20PFD的Datasheet PDF文件第12页  
FEATURES DESCRIPTIONS  
DESIGN CONSIDERATIONS (CON.)  
Remote On/Off  
The power module should be connected to a low  
ac-impedance input source. Highly inductive source  
impedances can affect the stability of the module. An  
input capacitance must be placed close to the modules  
input pins to filter ripple current and ensure module  
stability in the presence of inductive traces that supply  
the input voltage to the module.  
The DNL series power modules have an On/Off pin for  
remote On/Off operation. Both positive and negative  
On/Off logic options are available in the DNL series  
power modules.  
For positive logic module, connect an open collector  
(NPN) transistor or open drain (N channel) MOSFET  
between the On/Off pin and the GND pin (see figure 32).  
Positive logic On/Off signal turns the module ON during  
the logic high and turns the module OFF during the logic  
low. When the positive On/Off function is not used, leave  
the pin floating or tie to Vin (module will be On).  
Safety Considerations  
For safety-agency approval the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standards.  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements. The power module  
has extra-low voltage (ELV) outputs when all inputs are  
ELV.  
For negative logic module, the On/Off pin is pulled high  
with an external pull-up resistor (see figure 33) Negative  
logic On/Off signal turns the module OFF during logic  
high and turns the module ON during logic low. If the  
negative On/Off function is not used, leave the pin  
floating or tie to GND. (module will be On)  
The input to these units is to be provided with a  
maximum 15A of glass type fast-acting fuse in the  
ungrounded lead.  
Vin  
Vo  
ION/OFF  
RL  
On/Off  
GND  
Figure 29: Positive remote On/Off implementation  
Vo  
Vin  
Rpull-up  
ION/OFF  
RL  
On/Off  
GND  
Figure 30: Negative remote On/Off implementation  
Over-Current Protection  
To provide protection in an output over load fault  
condition, the unit is equipped with internal over-current  
protection. When the over-current protection is  
triggered, the unit enters hiccup mode. The units  
operate normally once the fault condition is removed.  
DS_DNL10SMD_07182012  
8