 浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第3页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第4页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第5页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第6页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第8页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第9页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第10页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第11页  
TEST CONFIGURATIONS  
DESIGN CONSIDERATIONS  
Input Source Impedance  
To maintain low noise and ripple at the input voltage, it is  
critical to use low ESR capacitors at the input to the  
module. A highly inductive source can affect the stability  
of the module. An input capacitance must be placed close  
to the modules input pins to filter ripple current and ensure  
module stability in the presence of inductive traces that  
supply the input voltage to the module.  
Safety Considerations  
Figure 25: Input reflected-ripple test setup  
For safety-agency approval the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standards.  
COPPER STRIP  
Vo  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements. The power module  
has extra-low voltage (ELV) outputs when all inputs are  
ELV.  
Resistive  
Load  
0.1uF  
10uF  
SCOPE  
ceramic ceramic  
GND  
The input to these units is to be provided with a  
maximum 20A fuse in the ungrounded lead.  
Note: Use a 10μF tantalum and 1μF capacitor. Scope  
measurement should be made using a BNC connector.  
Figure 26: Peak-peak output noise and startup transient  
Input Under voltage Lockout  
measurement test setup.  
At input voltages below the input under voltage lockout  
limit, the module operation is disabled. The module will  
begin to operate at an input voltage above the under  
voltage lockout turn-on threshold.  
CONTACT AND  
DISTRIBUTION LOSSES  
VI  
Vo  
II  
Io  
LOAD  
SUPPLY  
GND  
Over-Current Protection  
CONTACT RESISTANCE  
To provide protection in an output over load fault  
condition, the unit is equipped with internal over-current  
protection. When the over-current protection is triggered,  
the unit enters hiccup mode. The units operate normally  
once the fault condition is removed.  
Figure 27: Output voltage and efficiency measurement test  
setup  
Note: All measurements are taken at the module terminals. When  
the module is not soldered (via socket), place Kelvin  
connections at module terminals to avoid measurement  
errors due to contact resistance.  
Vo Io  
Vi Ii  
(  
)100 %  
DS_ DCM04S0A0S12PFA_10022013  