 浏览型号XB24CZ7RIS-004的Datasheet PDF文件第72页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第73页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第74页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第75页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第77页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第78页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第79页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第80页  
XBee®/XBeePRO® ZB SMT RF Modules  
A pushbutton and an LED can be  
connected to module pins 33 and  
28 respectively to support the  
commisioning pushbutton and  
Associate LED functionalities.  
Commissioning Pushbutton  
The commissioning pushbutton definitions provide a variety of simple functions to aid in deploying devices in a  
network. The commissioning button functionality on pin 33 is enabled by setting the D0 command to 1 (enabled  
by default).  
If module is not joined to a net-  
Button  
Presses  
If module is joined to a network  
work  
• Wakes an end device for  
30 seconds  
• Wakes an end device for  
30 seconds  
• Sends a node identifica-  
tion broadcast transmis-  
sion  
• Blinks a numeric error  
code on the Associate pin  
indicating the cause of  
join failure (see section  
6.4.2).  
1
• Sends a broadcast trans-  
mission to enable joining  
on the coordinator and all  
devices in the network for  
1 minute. (If joining is  
permanently enabled on a  
device (NJ = 0xFF), this  
action has no effect on  
that device.)  
• N/A  
2
• Causes the device to leave  
the PAN.  
• Issues ATRE to restore  
module parameters to  
default values, including  
ID and SC.  
• Issues ATRE to restore  
module parameters to  
default values, including  
ID and SC.  
• The device attempts to  
join a network based on  
its ID and SC settings.  
4
• The device attempts to  
join a network based on  
its ID and SC settings.  
Button presses may be simulated in software using the ATCB command. ATCB should be issued with a  
parameter set to the number of button presses to execute. (e.g. sending ATCB1 will execute the action(s)  
associated with a single button press.)  