 浏览型号XB24CZ7RIS-004的Datasheet PDF文件第70页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第71页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第72页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第73页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第75页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第76页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第77页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第78页  
6. Network Commissioning and Diagnostics  
Network commissioning is the process whereby devices in a mesh network are discovered and configured for operation.  
The XBee modules include several features to support device discovery and configuration. In addition to configuring  
devices, a strategy must be developed to place devices to ensure reliable routes.  
To accommodate these requirements, the XBee modules include various features to aid in device placement,  
configuration, and network diagnostics.  
Device Configuration  
XBee modules can be configured locally through serial commands (AT or API), or remotely through remote API  
commands. API devices can send configuration commands to set or read the configuration settings of any device in  
the network.  
Device Placement  
For a mesh network installation to be successful, the installer must be able to determine where to place individual  
XBee devices to establish reliable links throughout the mesh network.  
Link Testing  
A good way to measure the performance of a mesh network is to send unicast data through the network from  
one device to another to determine the success rate of many transmissions. To simplify link testing, the  
modules support a loopback cluster ID (0x12) on the data endpoint (0xE8). Any data sent to this cluster ID on  
the data endpoint will be transmitted back to the sender. This is shown in the figure below:  
The configuration steps to send data to the loopback cluster ID depend on the serial port mode as determined  
by the AP command.  
Transparent Mode  
To send data to the loopback cluster ID on the data endpoint of a remote device, set the CI command value to  
0x12. The SE and DE commands should be set to 0xE8 (default value). The DH and DL commands should be set  
to the address of the remote (0 for the coordinator, or the 64-bit address of the remote). After exiting command  
mode, any received serial characters will be transmitted to the remote device, and returned to the sender.  