XBee®/XBee‐PRO® ZB SMT RF Modules
Remote Command Response
Frame Type: 0x97
If a module receives a remote command response RF data frame in response to a Remote AT Command
Request, the module will send a Remote AT Command Response message out the serial port. Some commands
may send back multiple frames--for example, Node Discover (ND) command.
Frame Fields
Offset Example
0 0x7E
Description
Start Delimiter
Length
MSB 1 0x00
LSB 2 0x13
3 0x97
Number of bytes between the length and the checksum
Frame Type
This is the same value passed in to the request.
.
Frame ID
4 0x55
MSB 5 0x00
6 0x13
7 0xA2
8 0x00
64-bit Source
(remote) Address
The address of the remote radio returning this response.
9 0x40
A
P
I
10 0x52
11 0x2B
LSB 12 0xAA
MSB 13 0x7D
P
a
c
k
e
t
Set to the 16-bit network
address of the remote.
Set to 0xFFFE if
16-bit Source
(remote) Address
Frame-specific Data
LSB 14 0x84
unknown.
15 0x53
16 0x4C
AT Commands
Name of the command
0 = OK
1 = ERROR
Command Status
17 0x00
2 = Invalid Command
3 = Invalid Parameter
4 = Remote Command Transmission Failed
18 0x40
19 0x52
20 0x2B
21 0xAA
22 0xF0
Register data in binary format. If the register was set,
then this field is not returned.
Command Data
Checksum
0xFF - the 8 bit sum of bytes from offset 3 to this byte.
Example: If a remote command is sent to a remote device with 64-bit address 0x0013A200 40522BAA and
16-bit address 0x7D84 to query the SL command, and if the frame ID=0x55, the response is shown in the
example API frame in the table above.
© 2010 Digi International, Inc.
115